The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High-Resolution Mapping of Postinfarction Reentrant Ventricular Tachycardia: Electrophysiological Characterization of the Circuit
Open accessAbstract
Background: In vivo description of ventricular tachycardia (VT) circuits is limited by insufficient spatiotemporal resolution. We used a novel high-resolution mapping technology to characterize the electrophysiological properties of the postinfarction reentrant VT circuit. Methods: In 15 swine, myocardial infarction was induced by left anterior descending artery balloon occlusion. Animals were studied 6 to 8 weeks after myocardial infarction. Activation mapping of VTs was performed by using the Rhythmia mapping system. Activation time was based on a combination of bipolar and unipolar electrograms. The response to overdrive pacing from different zones of the circuit was examined. Results: A total of 56 monomorphic VTs were induced (3.8±2.1 per animal). Among these, 21 (37.5%) were hemodynamically stable and allowed mapping of the circuit. Isthmuses were 16.4±7.2 mm long and 7.4±2.8 mm wide. Conduction velocities were slowest at the inward curvature into the isthmus entrance (0.28±0.2 m/s), slightly faster at the outward curvature exit (0.40±0.3 m/s) and nearly normal at the central isthmus (0.62±0.2 m/s). In 3 animals, 2 VT morphologies with opposite axes sharing the same isthmus were mapped. Conduction velocities within the shared isthmus were dependent on the activation vector, consistently slower at the proximal curvature. Overdrive pacing from isthmus sites determined by activation mapping was consistent with entrainment criteria for isthmus. However, dimensions of the isthmus defined by entrainment exceeded dimensions of the isthmus measured by activation mapping by 32±18%. Conclusions: In postinfarction reentrant VT, conduction velocities are slowest at the proximal and distal curvatures. Entrainment mapping overestimates the true size of the isthmus. High-resolution activation mapping of VT may better guide ablation therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prophylactic Catheter Ablation for the Prevention of Defibrillator Therapy
Reddy, V. Y., Reynolds, M. R., Neuzil, P., Richardson, A. W., Taborsky, M., Jongnarangsin, K., Kralovec, S., Sediva, L., Ruskin, J. N., & Josephson, M. E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa065457 · Cited by 959
Self-citation
Cited by
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Self-citation
Metadata
- Authors
- Anter, E., Tschabrunn, C. M., Buxton, A. E., & Josephson, M. E.
- Venue
- Circulation
- Published
- 2016-07-26
- Volume
- 134
- Issue
- 4
- Pages
- 314-327
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2489172839
- Cited by
- 186
- References
- 1
- FWCI
- 18.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Resolution Mapping of Postinfarction Reentrant Ventricular Tachycardia: Electrophysiological Characterization of the Circuit. https://app.cochat.ai/papers/10.1161/circulationaha.116.021955
- The paper
- Anter, E., Tschabrunn, C. M., Buxton, A. E., & Josephson, M. E. (2016). High-Resolution Mapping of Postinfarction Reentrant Ventricular Tachycardia: Electrophysiological Characterization of the Circuit. Circulation. https://doi.org/10.1161/circulationaha.116.021955
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.