Long-Term Outcomes of the Ross Procedure Versus Mechanical Aortic Valve Replacement: Propensity-Matched Cohort Study
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background: The ideal aortic valve substitute in young and middle-aged adults remains unknown. We sought to compare the long-term outcomes of patients undergoing the Ross procedure and those receiving a mechanical aortic valve replacement (AVR). Methods: From 1990 to 2014, 258 patients underwent a Ross procedure and 1444 had a mechanical AVR at a single institution. Patients were matched into 208 pairs through the use of a propensity score. Mean age was 37.2±10.2 years, and 63% were male. Mean follow-up was 14.2±6.5 years. Results: Overall survival was equivalent (Ross versus AVR: hazard ratio, 0.91, 95% confidence interval, 0.38–2.16; P =0.83), although freedom from cardiac- and valve-related mortality was improved in the Ross group (Ross versus AVR: hazard ratio, 0.22; 95% confidence interval, 0.034–0.86; P =0.03). Freedom from reintervention was equivalent after both procedures (Ross versus AVR: hazard ratio, 1.86; 95% confidence interval, 0.76–4.94; P =0.18). Long-term freedom from stroke or major bleeding was superior after the Ross procedure (Ross versus AVR: hazard ratio, 0.09; 95% confidence interval, 0.02–0.31; P <0.001). Conclusions: Long-term survival and freedom from reintervention were comparable between the Ross procedure and mechanical AVR. However, the Ross procedure was associated with improved freedom from cardiac- and valve-related mortality and a significant reduction in the incidence of stroke and major bleeding. In specialized centers, the Ross procedure represents an excellent option and should be considered for young and middle-aged adults undergoing AVR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hammermeister, K., Sethi, G. K., Henderson, W. G., Grover, F. L., Oprian, C., & Rahimtoola, S. H. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00834-2 · Cited by 1,144
Guidelines for reporting mortality and morbidity after cardiac valve interventions
Akins, C. W., Miller, D. C., Turina, M. I., Kouchoukos, N. T., Blackstone, E. H., Grunkemeier, G. L., Takkenberg, J. J. M., David, T. E., Butchart, E. G., Adams, D. H., et al. (2008) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2007.12.002 · Cited by 665
Self-citationObserved and relative survival after aortic valve replacement
Kvidal, P., Bergström, P. R., Hörte, L.-G., & Ståhle, E. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00584-7 · Cited by 525 · cited 1×
“001 Surgeon A 2 (1) 42 (20) Surgeon B 201 (96) 102 (49) Other surgeon 5 (2) 64 (31) Previous cardiac interventions, n (%) Any previous cardiac surgery 41 (19.”
BackgroundPropensity Scores in Cardiovascular Research
D’Agostino, R. B. (2007) · Circulation · doi:10.1161/circulationaha.105.594952 · Cited by 451
El-Hamamsy, I., Eryigit, Z., Stevens, L.-M., Sarang, Z., George, R., Clark, L., Melina, G., Takkenberg, J. J., & Yacoub, M. H. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60828-8 · Cited by 377
Heneghan, C., Ward, A., Perera, R., Bankhead, C., Fuller, A., Stevens, R., Bradford, K., Tyndel, S., Alonso-Coello, P., Ansell, J., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(11)61294-4 · Cited by 372
Choice of Prosthetic Heart Valve in Adults
Rahimtoola, S. H. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.10.085 · Cited by 355
Puskas, J., Gerdisch, M., Nichols, D., Quinn, R., Anderson, C., Rhenman, B., Fermin, L., McGrath, M., Kong, B., Hughes, C., et al. (2014) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2014.01.004 · Cited by 286
The Ross Procedure: A Systematic Review and Meta-Analysis
Takkenberg, J. J. M., Klieverik, L. M. A., Schoof, P. H., van Suylen, R.-J., van Herwerden, L. A., Zondervan, P. E., Roos-Hesselink, J. W., Eijkemans, M. J. C., Yacoub, M. H., & Bogers, A. J. J. C. (2009) · Circulation · doi:10.1161/circulationaha.107.726349 · Cited by 255
Twenty-year comparison of tissue and mechanical valve replacement
Khan, S. S., Trento, A., DeRobertis, M. A., et al. (2001) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2001.115238 · Cited by 229
Cited by
Next-generation tissue-engineered heart valves with repair, remodelling and regeneration capacity
Fioretta, E. S., Motta, S. E., Lintas, V., Loerakker, S., Parker, K. K., Baaijens, F. P. T., Falk, V., Hoerstrup, S. P., & Emmert, M. Y. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0422-8 · Cited by 262
Metadata
- Authors
- Mazine, A., David, T. E., Rao, V., Hickey, E. J., Christie, S., Manlhiot, C., & Ouzounian, M.
- Venue
- Circulation
- Published
- 2016-08-23
- Volume
- 134
- Issue
- 8
- Pages
- 576-585
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2516062397
- Cited by
- 174
- References
- 24
- FWCI
- 11.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.