Background: Prenatal diagnosis of coarctation of the aorta (CoA) is still challenging and affected by high rates of false-positive diagnoses. The aim of this study was to ascertain the strength of association and to quantify the diagnostic accuracy of different ultrasound signs in predicting CoA prenatally. Methods: Medline, Embase, CINAHL, and Cochrane databases were searched. Random-effects and hierarchical summary receiver operating characteristic model meta-analyses were used to analyze the data. Results: Seven hundred ninety-four articles were identified, and 12 (922 fetuses at risk for CoA) articles were included. Mean mitral valve diameter z score was lower ( P <0.001) and the mean tricuspid valve diameter z score was higher in fetuses with CoA than in those without CoA ( P =0.01). Mean aortic valve diameter z score was lower in fetuses with CoA than in healthy fetuses ( P ≤0.001), but the ascending aorta diameter, expressed as z score or millimeters, was similar between groups ( P =0.07 and 0.47, respectively). Mean aortic isthmus diameter z scores measured either in sagittal ( P =0.02) or in 3-vessel trachea view ( P <0.001) were lower in fetuses with CoA. Conversely, the mean pulmonary artery diameter z score, the right/left ventricular and pulmonary artery/ascending aorta diameter ratios were higher ( P <0.001, P =0.02, and P =0.02, respectively) in fetuses with CoA in comparison with controls, although aortic isthmus/arterial duct diameter ratio was lower in fetuses with CoA than in those without CoA ( P <0.001). The presence of coarctation shelf and aortic arch hypoplasia were more common in fetuses with CoA than in controls (odds ratio, 26.0; 95% confidence interval, 4.42–153; P <0.001 and odds ratio, 38.2; 95% confidence interval, 3.01–486; P =0.005), whereas persistent left superior vena cava ( P =0.85), ventricular septal defect ( P =0.12), and bicuspid aortic valve ( P =0.14) did not carry an increased risk for this anomaly. Multiparametric diagnostic models integrating different ultrasound signs for the detection of CoA were associated with an increased detection rate. Conclusions: The detection rate of CoA may improve when a multiple-criteria prediction model is adopted. Further large multicenter studies sharing the same imaging protocols are needed to develop objective models for risk assessment in these fetuses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.116.024068

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Familiari, A., Morlando, M., Khalil, A., Sonesson, S.-E., Scala, C., Rizzo, G., Del Sordo, G., Vassallo, C., Elena Flacco, M., Manzoli, L., Lanzone, A., Scambia, G., Acharya, G., & D’Antonio, F.
Venue
Circulation
Published
2017-02-21
Volume
135
Issue
8
Pages
772-785
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2562794221
Cited by
169
References
4
FWCI
7.36
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.