The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Transcatheter Treatment of Severe Tricuspid Regurgitation With the Edge-to-Edge MitraClip Technique
Open accessAbstract
Background: Current surgical and medical treatment options for severe tricuspid regurgitation (TR) are limited, and additional interventional approaches are required. In the present observational study, the safety and feasibility of transcatheter repair of chronic severe TR with the MitraClip system were evaluated. In addition, the effects on clinical symptoms were assessed. Methods: Patients with heart failure symptoms and severe TR on optimal medical treatment were treated with the MitraClip system. Safety, defined as periprocedural adverse events such as death, myocardial infarction, stroke, or cardiac tamponade, and feasibility, defined as successful implantation of 1 or more MitraClip devices and reduction of TR by at least 1 grade, were evaluated before discharge and after 30 days. In addition, functional outcome, defined as changes in New York Heart Assocation class and 6-minute walking distance, were assessed. Results: We included 64 consecutive patients (mean age 76.6±10 years) deemed unsuitable for surgery who underwent MitraClip treatment for chronic, severe TR for compassionate use. Functional TR was present in 88%; in addition, 22 patients were also treated with the MitraClip system for mitral regurgitation as a combined procedure. The degree of TR was severe or massive in 88% of patients before the procedure. The MitraClip device was successfully implanted in the tricuspid valve in 97% of the cases. After the procedure, TR was reduced by at least 1 grade in 91% of the patients, thereof 4% that were reduced from massive to severe. In 13% of patients, TR remained severe after the procedure. Significant reductions in effective regurgitant orifice area (0.9±0.3cm 2 versus 0.4±0.2cm 2 ; P <0.001), vena contracta width (1.1±0.5 cm versus 0.6±0.3 cm; P =0.001), and regurgitant volume (57.2±12.8 mL/beat versus 30.8±6.9 mL/beat; P <0.001) were observed. No intraprocedural deaths, cardiac tamponade, emergency surgery, stroke, myocardial infarction, or major vascular complications occurred. Three (5%) in-hospital deaths occurred. New York Heart Association class was significantly improved ( P <0.001), and 6-minute walking distance increased significantly (165.9±102.5 m versus 193.5±115.9 m; P =0.007). Conclusions: Transcatheter treatment of TR with the MitraClip system seems to be safe and feasible in this cohort of preselected patients. Initial efficacy analysis showed encouraging reduction of TR, which may potentially result in improved clinical outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.176857 · Cited by 8,495
Rudski, L. G., Lai, W. W., Afilalo, J., Hua, L., Handschumacher, M. D., Chandrasekaran, K., Solomon, S. D., Louie, E. K., & Schiller, N. B. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.05.010 · Cited by 7,049
Guidelines on the management of valvular heart disease (version 2012)
Authors/Task Force Members, Vahanian, A., Alfieri, O., Andreotti, F., Antunes, M. J., Barón-Esquivias, G., Baumgartner, H., Borger, M. A., Carrel, T. P., De Bonis, M., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs109 · Cited by 3,559
Self-citationNishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000031 · Cited by 2,905
Percutaneous Repair or Surgery for Mitral Regurgitation
Feldman, T., Foster, E., Glower, D. D., Kar, S., Rinaldi, M. J., Fail, P. S., Smalling, R. W., Siegel, R., Rose, G. A., Engeron, E., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1009355 · Cited by 2,183
Definitions and Diagnosis of Pulmonary Hypertension
Hoeper, M. M., Bogaard, H. J., Condliffe, R., Frantz, R., Khanna, D., Kurzyna, M., Langleben, D., Manes, A., Satoh, T., Torres, F., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.10.032 · Cited by 1,766
Impact of tricuspid regurgitation on long-term survival
Nath, J., Foster, E., & Heidenreich, P. A. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.09.036 · Cited by 1,677
Lancellotti, P., Moura, L., Pierard, L. A., Agricola, E., Popescu, B. A., Tribouilloy, C., Hagendorff, A., Monin, J. L., Badano, L., Zamorano, J. L., et al. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq031 · Cited by 1,545
The Tricuspid Valve: Current Perspective and Evolving Management of Tricuspid Regurgitation
Rogers, J. H., & Bolling, S. F. (2009) · Circulation · doi:10.1161/circulationaha.108.842773 · Cited by 389
Tricuspid Valve Tethering Predicts Residual Tricuspid Regurgitation After Tricuspid Annuloplasty
Fukuda, S., Song, J.-M., Gillinov, A. M., McCarthy, P. M., Daimon, M., Kongsaerepong, V., Thomas, J. D., & Shiota, T. (2005) · Circulation · doi:10.1161/01.cir.0000156449.49998.51 · Cited by 333
Cited by
Heart Disease and Stroke Statistics—2020 Update: A Report From the American Heart Association
Virani, S. S., Alonso, A., Benjamin, E. J., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Chang, A. R., Cheng, S., Delling, F. N., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000757 · Cited by 9,175
Heart Disease and Stroke Statistics—2019 Update: A Report From the American Heart Association
Benjamin, E. J., Muntner, P., Alonso, A., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Chang, A. R., Cheng, S., Das, S. R., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000659 · Cited by 9,036
Metadata
- Authors
- Nickenig, G., Kowalski, M., Hausleiter, J., Braun, D., Schofer, J., Yzeiraj, E., Rudolph, V., Friedrichs, K., Maisano, F., Taramasso, M., Fam, N., Bianchi, G., Bedogni, F., Denti, P., Alfieri, O., Latib, A., Colombo, A., Hammerstingl, C., & Schueler, R.
- Venue
- Circulation
- Published
- 2017-05-09
- Volume
- 135
- Issue
- 19
- Pages
- 1802-1814
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2598256158
- Cited by
- 365
- References
- 18
- FWCI
- 36.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transcatheter Treatment of Severe Tricuspid Regurgitation With the Edge-to-Edge MitraClip Technique. https://app.cochat.ai/papers/10.1161/circulationaha.116.024848
- The paper
- Nickenig, G., Kowalski, M., Hausleiter, J., Braun, D., Schofer, J., Yzeiraj, E., Rudolph, V., Friedrichs, K., Maisano, F., Taramasso, M., Fam, N., Bianchi, G., Bedogni, F., Denti, P., Alfieri, O., Latib, A., Colombo, A., Hammerstingl, C., & Schueler, R. (2017). Transcatheter Treatment of Severe Tricuspid Regurgitation With the Edge-to-Edge MitraClip Technique. Circulation. https://doi.org/10.1161/circulationaha.116.024848
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.