The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Impact of the Clinical Frailty Scale on Outcomes After Transcatheter Aortic Valve Replacement
Open accessAbstract
Background: The semiquantitative Clinical Frailty Scale (CFS) is a simple tool to assess patients’ frailty and has been shown to correlate with mortality in elderly patients even when evaluated by nongeriatricians. The aim of the current study was to determine the prognostic value of CFS in patients who underwent transcatheter aortic valve replacement. Methods: We utilized the OCEAN (Optimized Catheter Valvular Intervention) Japanese multicenter registry to review data of 1215 patients who underwent transcatheter aortic valve replacement. Patients were categorized into 5 groups based on the CFS stages: CFS 1-3, CFS 4, CFS 5, CFS 6, and CFS ≥7. We subsequently evaluated the relationship between CFS grading and other indicators of frailty, including body mass index, serum albumin, gait speed, and mean hand grip. We also assessed differences in baseline characteristics, procedural outcomes, and early and midterm mortality among the 5 groups. Results: Patient distribution into the 5 CFS groups was as follows: 38.0% (CFS 1-3), 32.9% (CFS4), 15.1% (CFS 5), 10.0% (CFS 6), and 4.0% (CFS ≥7). The CFS grade showed significant correlation with body mass index (Spearman’s ρ=−0.077, P =0.007), albumin (ρ=−0.22, P <0.001), gait speed (ρ=−0.28, P <0.001), and grip strength (ρ=−0.26, P <0.001). Cumulative 1-year mortality increased with increasing CFS stage (7.2%, 8.6%. 15.7%, 16.9%, 44.1%, P <0.001). In a Cox regression multivariate analysis, the CFS (per 1 category increase) was an independent predictive factor of increased late cumulative mortality risk (hazard ratio, 1.28; 95% confidence interval, 1.10–1.49; P <0.001). Conclusions: In addition to reflecting the degree of frailty, the CFS was a useful marker for predicting late mortality in an elderly transcatheter aortic valve replacement cohort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frailty in Older Adults: Evidence for a Phenotype
Fried, L. P., Tangen, C. M., Walston, J., Newman, A. B., Hirsch, C., Gottdiener, J., Seeman, T., Tracy, R., Kop, W. J., Burke, G., et al. (2001) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/56.3.m146 · Cited by 24,907
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Clegg, A., Young, J., Iliffe, S., Rikkert, M. O., & Rockwood, K. (2013) · The Lancet · doi:10.1016/s0140-6736(12)62167-9 · Cited by 9,503
A global clinical measure of fitness and frailty in elderly people
Rockwood, K. (2005) · Canadian Medical Association Journal · doi:10.1503/cmaj.050051 · Cited by 8,968
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Guidelines on the management of valvular heart disease (version 2012)
Authors/Task Force Members, Vahanian, A., Alfieri, O., Andreotti, F., Antunes, M. J., Barón-Esquivias, G., Baumgartner, H., Borger, M. A., Carrel, T. P., De Bonis, M., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs109 · Cited by 3,559
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,368
Registry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, B., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114705 · Cited by 1,228
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2013) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2012.09.002 · Cited by 918
Cited by
Frailty in Older Adults Undergoing Aortic Valve Replacement
Afilalo, J., Lauck, S., Kim, D. H., Lefèvre, T., Piazza, N., Lachapelle, K., Martucci, G., Lamy, A., Labinaz, M., Peterson, M. D., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.06.024 · Cited by 818
Atherton, J. J., Sindone, A., De Pasquale, C. G., Driscoll, A., MacDonald, P. S., Hopper, I., Kistler, P. M., Briffa, T., Wong, J., Abhayaratna, W., et al. (2018) · Heart, Lung and Circulation · doi:10.1016/j.hlc.2018.06.1042 · Cited by 431
Metadata
- Authors
- Shimura, T., Yamamoto, M., Kano, S., Kagase, A., Kodama, A., Koyama, Y., Tsuchikane, E., Suzuki, T., Otsuka, T., Kohsaka, S., Tada, N., Yamanaka, F., Naganuma, T., Araki, M., Shirai, S., Watanabe, Y., Hayashida, K., Yashima, F., Inohara, T., Kakefuda, Y., Arai, T., Yanagisawa, R., Tanaka, M., Kawakami, T., Maekawa, Y., Takashi, K., Yoshitake, A., Iida, Y., Yamazaki, M., Shimizu, H., Yamada, Y., Jinzaki, M., Tsuruta, H., Itabashi, Y., Murata, M., Kawakami, M., Fukui, S., Sano, M., Fukuda, K., Hosoba, S., Sato, H., Teramoto, T., Kimura, M., Sago, M., Tsunaki, T., Watarai, S., Tsuzuki, M., Irokawa, K., Shimizu, K., Kobayashi, T., Okawa, Y., Miyasaka, M., Enta, Y., Shishido, K., Ochiai, T., Yamabe, T., Noguchi, K., Saito, S., Kawamoto, H., Onishi, H., Yabushita, H., Mitomo, S., Nakamura, S., Yamawaki, M., Akatsu, Y., Honda, Y., Takama, T., Isotani, A., Hayashi, M., Kamioka, N., Miura, M., Morinaga, T., Kawaguchi, T., Yano, M., Hanyu, M., Arai, Y., Tsubota, H., Kudo, M., Kuroda, Y., Kataoka, A., Hioki, H., Nara, Y., Kawashima, H., Nagura, F., Nakashima, M., Sasaki, K., Nishikawa, J., Shimokawa, T., Harada, T., & Kozuma, K.
- Venue
- Circulation
- Published
- 2017-05-23
- Volume
- 135
- Issue
- 21
- Pages
- 2013-2024
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2595224310
- Cited by
- 301
- References
- 20
- FWCI
- 21.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of the Clinical Frailty Scale on Outcomes After Transcatheter Aortic Valve Replacement. https://app.cochat.ai/papers/10.1161/circulationaha.116.025630
- The paper
- Shimura, T., Yamamoto, M., Kano, S., Kagase, A., Kodama, A., Koyama, Y., Tsuchikane, E., Suzuki, T., Otsuka, T., Kohsaka, S., Tada, N., Yamanaka, F., Naganuma, T., Araki, M., Shirai, S., Watanabe, Y., Hayashida, K., Yashima, F., Inohara, T., . . . Kozuma, K. (2017). Impact of the Clinical Frailty Scale on Outcomes After Transcatheter Aortic Valve Replacement. Circulation. https://doi.org/10.1161/circulationaha.116.025630
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.