Abstract

Background: Elevated pulmonary artery (PA) pressures in patients with heart failure are associated with a high risk for hospitalization and mortality. Recent clinical trial evidence demonstrated a direct relationship between lowering remotely monitored PA pressures and heart failure hospitalization risk reduction with a novel implantable PA pressure monitoring system (CardioMEMS HF System, St. Jude Medical). This study examines PA pressure changes in the first 2000 US patients implanted in general practice use. Methods: Deidentified data from the remote monitoring Merlin.net (St. Jude Medical) database were used to examine PA pressure trends from the first consecutive 2000 patients with at least 6 months of follow-up. Changes in PA pressures were evaluated with an area under the curve methodology to estimate the total sum increase or decrease in pressures (mm Hg-day) during the follow-up period relative to the baseline pressure. As a reference, the PA pressure trends were compared with the historic CHAMPION clinical trial (CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in New York Heart Association [NYHA] Functional Class III Heart Failure Patients). The area under the curve results are presented as mean±2 SE, and P values comparing the area under the curve of the general-use cohort with outcomes in the CHAMPION trial were computed by the t test with equal variance. Results: Patients were on average 70±12 years old; 60% were male; 34% had preserved ejection fraction; and patients were followed up for an average of 333±125 days. At implantation, the mean PA pressure for the general-use patients was 34.9±10.2 mm Hg compared with 31.3±10.9 mm Hg for CHAMPION treatment and 32.0±10.5 mm Hg for CHAMPION control groups. The general-use patients had an area under the curve of −32.8 mm Hg-day at the 1-month time mark, −156.2 mm Hg-day at the 3-month time mark, and −434.0 mm Hg-day after 6 months of hemodynamic guided care, which was significantly lower than the treatment group in the CHAMPION trial. Patients consistently transmitted pressure information with a median of 1.27 days between transmissions after 6 months. Conclusions: The first 2000 general-use patients managed with hemodynamic-guided heart failure care had higher PA pressures at baseline and experienced greater reduction in PA pressure over time compared with the pivotal CHAMPION clinical trial. These data demonstrate that general use of implantable hemodynamic technology in a nontrial setting leads to significant lowering of PA pressures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.116.026184

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

Metadata

Authors
Heywood, J. T., Jermyn, R., Shavelle, D., Abraham, W. T., Bhimaraj, A., Bhatt, K., Sheikh, F., Eichorn, E., Lamba, S., Bharmi, R., Agarwal, R., Kumar, C., & Stevenson, L. W.
Venue
Circulation
Published
2017-04-18
Volume
135
Issue
16
Pages
1509-1517
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2885511417
Cited by
148
References
16
FWCI
13.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.