The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Optimizing a Drone Network to Deliver Automated External Defibrillators
Open accessAbstract
Background: Public access defibrillation programs can improve survival after out-of-hospital cardiac arrest, but automated external defibrillators (AEDs) are rarely available for bystander use at the scene. Drones are an emerging technology that can deliver an AED to the scene of an out-of-hospital cardiac arrest for bystander use. We hypothesize that a drone network designed with the aid of a mathematical model combining both optimization and queuing can reduce the time to AED arrival. Methods: We applied our model to 53 702 out-of-hospital cardiac arrests that occurred in the 8 regions of the Toronto Regional RescuNET between January 1, 2006, and December 31, 2014. Our primary analysis quantified the drone network size required to deliver an AED 1, 2, or 3 minutes faster than historical median 911 response times for each region independently. A secondary analysis quantified the reduction in drone resources required if RescuNET was treated as a large coordinated region. Results: The region-specific analysis determined that 81 bases and 100 drones would be required to deliver an AED ahead of median 911 response times by 3 minutes. In the most urban region, the 90th percentile of the AED arrival time was reduced by 6 minutes and 43 seconds relative to historical 911 response times in the region. In the most rural region, the 90th percentile was reduced by 10 minutes and 34 seconds. A single coordinated drone network across all regions required 39.5% fewer bases and 30.0% fewer drones to achieve similar AED delivery times. Conclusions: An optimized drone network designed with the aid of a novel mathematical model can substantially reduce the AED delivery time to an out-of-hospital cardiac arrest event.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Public-Access Defibrillation and Survival after Out-of-Hospital Cardiac Arrest
(2004) · New England Journal of Medicine · doi:10.1056/nejmoa040566 · Cited by 1,130
Weisfeldt, M. L., Sitlani, C. M., Ornato, J. P., Rea, T., Aufderheide, T. P., Davis, D., Dreyer, J., Hess, E. P., Jui, J., Maloney, J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.077 · Cited by 538
Self-citationOpportunities and challenges with autonomous micro aerial vehicles
Kumar, V., & Michael, N. (2012) · The International Journal of Robotics Research · doi:10.1177/0278364912455954 · Cited by 472
Quality and efficiency of bystander CPR
Van Hoeyweghen, R. J., Bossaert, L. L., Mullie, A., Calle, P., Martens, P., Buylaert, W. A., & Delooz, H. (1993) · Resuscitation · doi:10.1016/0300-9572(93)90162-j · Cited by 451
Ventricular Tachyarrhythmias after Cardiac Arrest in Public versus at Home
Weisfeldt, M. L., Everson-Stewart, S., Sitlani, C., Rea, T., Aufderheide, T. P., Atkins, D. L., Bigham, B., Brooks, S. C., Foerster, C., Gray, R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1010663 · Cited by 316
Self-citationMorrison, L. J., Nichol, G., Rea, T. D., Christenson, J., Callaway, C. W., Stephens, S., Pirrallo, R. G., Atkins, D. L., Davis, D. P., Idris, A. H., et al. (2008) · Resuscitation · doi:10.1016/j.resuscitation.2008.02.020 · Cited by 283
Self-citationLocating AED Enabled Medical Drones to Enhance Cardiac Arrest Response Times
Pulver, A., Wei, R., & Mann, C. (2016) · Prehospital Emergency Care · doi:10.3109/10903127.2015.1115932 · Cited by 188
Folke, F., Gislason, G. H., Lippert, F. K., Nielsen, S. L., Weeke, P., Hansen, M. L., Fosbøl, E. L., Andersen, S. S., Rasmussen, S., Schramm, T. K., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.924423 · Cited by 179
An Automated Battery Management System to Enable Persistent Missions With Multiple Aerial Vehicles
Üre, N. K., Chowdhary, G. V., Toksoz, T., How, J. P., Vavrina, M. A., & Vian, J. L. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2294805 · Cited by 163
Community Lay Rescuer Automated External Defibrillation Programs
Aufderheide, T. P., Hazinski, M. F., Nichol, G., Steffens, S. S., Buroker, A. B., McCune, R., Stapleton, E., Nadkarni, V., Potts, J., Ramirez, R. R., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.172289 · Cited by 153
Overcoming Spatial and Temporal Barriers to Public Access Defibrillators Via Optimization
Sun, C. L. F., Demirtas, D., Brooks, S. C., Morrison, L. J., & Chan, T. C. Y. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.03.609 · Cited by 115
Self-citationCardiac arrest in private locations: different strategies are needed to improve outcome
Swor, R. A., Jackson, R. E., Compton, S. A., Domeier, R. M., Zalenski, R. J., Honeycutt, L. J., Kuhn, G. J., Frederiksen, S., & Pascual, R. G. (2003) · Resuscitation · doi:10.1016/s0300-9572(03)00118-7 · Cited by 110
Out-of-hospital cardiac arrest frequency and survival: Evidence for temporal variability
Brooks, S. C., Schmicker, R. H., Rea, T. D., Aufderheide, T. P., Davis, D. P., Morrison, L. J., Sahni, R., Sears, G. K., Griffiths, D. E., Sopko, G. S., et al. (2009) · Resuscitation · doi:10.1016/j.resuscitation.2009.10.021 · Cited by 109
Self-citationOptimizing the Deployment of Public Access Defibrillators
Chan, T. C. Y., Demirtas, D., & Kwon, R. H. (2016) · Management Science · doi:10.1287/mnsc.2015.2312 · Cited by 96
Self-citationCost-effectiveness of automated external defibrillator deployment in selected public locations
Cram, P. M., Vijan, S. S., & Fendrick, A. M. (2003) · Journal of General Internal Medicine · doi:10.1046/j.1525-1497.2003.21139.x · Cited by 84
Mission Health Management for 24/7 Persistent Surveillance Operations
Valenti, M., Dale, D., How, J. P., de Farias, D. P., & Vian, J. L. (2007) · AIAA Guidance, Navigation, and Control Conference and Exhibit · doi:10.2514/6.2007-6508 · Cited by 75
Out-of-hospital cardiac arrest in high-rise buildings: delays to patient care and effect on survival
Drennan, I. R., Strum, R. P., Byers, A., et al. (2016) · Canadian Medical Association Journal · doi:10.1503/cmaj.150544 · Cited by 65
Self-citationThe Effectiveness and Cost Effectiveness of Public‐Access Defibrillation
Winkle, R. A. (2010) · Clinical Cardiology · doi:10.1002/clc.20790 · Cited by 60
Cardiac arrest in public locations—An independent predictor for better outcome?
Eisenburger, P., Sterz, F. R., Haugk, M., Scheinecker, W., Holzer, M. S., Koreny, M., Kaff, A., Laggner, A. N., & Herkner, H. (2006) · Resuscitation · doi:10.1016/j.resuscitation.2006.02.002 · Cited by 47
Lin, S., Morrison, L. J., & Brooks, S. C. (2011) · Resuscitation · doi:10.1016/j.resuscitation.2010.12.006 · Cited by 46
Self-citationFeasiblity of motion primitives for choreographed quadrocopter flight
Schoellig, A. P., Hehn, M., Lupashin, S., & D’Andrea, R. (2011) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2011.5991482 · Cited by 42
Self-citationCost-effectiveness of automated external defibrillators in public places: con
Pell, J. P., Walker, A., & Cobbe, S. M. (2006) · Current Opinion in Cardiology · doi:10.1097/hco.0b013e3280118fec · Cited by 26
Cited by
Safe Learning in Robotics: From Learning-Based Control to Safe Reinforcement Learning
Brunke, L., Greeff, M., Hall, A. W., Yuan, Z., Zhou, S., Panerati, J., & Schoellig, A. P. (2022) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-042920-020211 · Cited by 769
Self-citationEuropean Resuscitation Council Guidelines 2021: Basic Life Support
Olasveengen, T. M., Semeraro, F., Ristagno, G., Castren, M., Handley, A., Kuzovlev, A., Monsieurs, K. G., Raffay, V., Smyth, M., Soar, J., et al. (2021) · Resuscitation · doi:10.1016/j.resuscitation.2021.02.009 · Cited by 734
Cheng, A., Nadkarni, V. M., Mancini, M. B., Hunt, E. A., Sinz, E. H., Merchant, R. M., Donoghue, A., Duff, J. P., Eppich, W., Auerbach, M., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000583 · Cited by 418
Applications and Research avenues for drone-based models in logistics: A classification and review
Moshref-Javadi, M., & Winkenbach, M. (2021) · Expert Systems with Applications · doi:10.1016/j.eswa.2021.114854 · Cited by 391
Harrington, R. A., Califf, R. M., Balamurugan, A., Brown, N., Benjamin, R. M., Braund, W. E., Hipp, J., Konig, M., Sanchez, E., & Joynt Maddox, K. E. (2020) · Circulation · doi:10.1161/cir.0000000000000753 · Cited by 385
Metadata
- Authors
- Boutilier, J. J., Brooks, S. C., Janmohamed, A., Byers, A., Buick, J. E., Zhan, C., Schoellig, A. P., Cheskes, S., Morrison, L. J., & Chan, T. C. Y.
- Venue
- Circulation
- Published
- 2017-06-20
- Volume
- 135
- Issue
- 25
- Pages
- 2454-2465
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2591892707
- Cited by
- 274
- References
- 22
- FWCI
- 41.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.