The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Conscious Sedation Versus General Anesthesia for Transcatheter Aortic Valve Replacement: Insights from the National Cardiovascular Data Registry Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry
Abstract
Background: Conscious sedation is used during transcatheter aortic valve replacement (TAVR) with limited evidence as to the safety and efficacy of this practice. Methods: The National Cardiovascular Data Registry Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry was used to characterize the anesthesia choice and clinical outcomes of all US patients undergoing elective percutaneous transfemoral TAVR between April 1, 2014, and June 30, 2015. Raw and inverse probability of treatment-weighted analyses were performed to compare patients undergoing TAVR with general anesthesia with patients undergoing TAVR with conscious sedation on an intention-to-treat basis for the primary outcome of in-hospital mortality, and secondary outcomes including 30-day mortality, in-hospital and 30-day death/stroke, procedural success, intensive care unit and hospital length-of-stay, and rates of discharge to home. Post hoc falsification end point analyses were performed to evaluate for residual confounding. Results: Conscious sedation was used in 1737/10 997 (15.8%) cases with a significant trend of increasing usage over the time period studied ( P for trend<0.001). In raw analyses, intraprocedural success with conscious sedation and general anesthesia was similar (98.2% versus 98.5%, P =0.31). The conscious sedation group was less likely to experience in-hospital (1.6% versus 2.5%, P =0.03) and 30-day death (2.9% versus 4.1%, P =0.03). Conversion from conscious sedation to general anesthesia was noted in 102 of 1737 (5.9%) of conscious sedation cases. After inverse probability of treatment-weighted adjustment for 51 covariates, conscious sedation was associated with lower procedural success (97.9% versus 98.6%, P <0.001) and a reduced rate of mortality at the in-hospital (1.5% versus 2.4%, P <0.001) and 30-day (2.3% versus 4.0%, P <0.001) time points. Conscious sedation was associated with reductions in procedural inotrope requirement, intensive care unit and hospital length of stay (6.0 versus 6.5 days, P <0.001), and combined 30-day death/stroke rates (4.8% versus 6.4%, P <0.001). Falsification end point analyses of vascular complications, bleeding, and new pacemaker/defibrillator implantation demonstrated no significant differences between groups after adjustment. Conclusions: In US practice, conscious sedation is associated with briefer length of stay and lower in-hospital and 30-day mortality in comparison with TAVR with general anesthesia in both unadjusted and adjusted analyses. These results suggest the safety of conscious sedation in this population, although comparative effectiveness analyses using observational data cannot definitively establish the superiority of one technique over another.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citation
Cited by
Zoghbi, W. A., Asch, F. M., Bruce, C., Gillam, L. D., Grayburn, P. A., Hahn, R. T., Inglessis, I., Islam, A. M., Lerakis, S., Little, S. H., et al. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.01.003 · Cited by 439
Wood, D. A., Lauck, S. B., Cairns, J. A., Humphries, K. H., Cook, R., Welsh, R., Leipsic, J., Genereux, P., Moss, R., Jue, J., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.12.020 · Cited by 259
Metadata
- Authors
- Hyman, M. C., Vemulapalli, S., Szeto, W. Y., Stebbins, A., Patel, P. A., Matsouaka, R. A., Herrmann, H. C., Anwaruddin, S., Kobayashi, T., Desai, N. D., Vallabhajosyula, P., McCarthy, F. H., Li, R., Bavaria, J. E., & Giri, J.
- Venue
- Circulation
- Published
- 2017-11-28
- Volume
- 136
- Issue
- 22
- Pages
- 2132-2140
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2751096607
- Cited by
- 231
- References
- 2
- FWCI
- 22.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Conscious Sedation Versus General Anesthesia for Transcatheter Aortic Valve Replacement: Insights from the National Cardiovascular Data Registry Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. https://app.cochat.ai/papers/10.1161/circulationaha.116.026656
- The paper
- Hyman, M. C., Vemulapalli, S., Szeto, W. Y., Stebbins, A., Patel, P. A., Matsouaka, R. A., Herrmann, H. C., Anwaruddin, S., Kobayashi, T., Desai, N. D., Vallabhajosyula, P., McCarthy, F. H., Li, R., Bavaria, J. E., & Giri, J. (2017). Conscious Sedation Versus General Anesthesia for Transcatheter Aortic Valve Replacement: Insights from the National Cardiovascular Data Registry Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. Circulation. https://doi.org/10.1161/circulationaha.116.026656
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.