Comparison Between Patent Ductus Arteriosus Stent and Modified Blalock-Taussig Shunt as Palliation for Infants With Ductal-Dependent Pulmonary Blood Flow: Insights From the Congenital Catheterization Research Collaborative
Abstract
Background: Infants with ductal-dependent pulmonary blood flow may undergo palliation with either a patent ductus arteriosus (PDA) stent or a modified Blalock-Taussig (BT) shunt. A balanced multicenter comparison of these 2 approaches is lacking. Methods: Infants with ductal-dependent pulmonary blood flow palliated with either a PDA stent or a BT shunt from January 2008 to November 2015 were reviewed from the 4 member centers of the Congenital Catheterization Research Collaborative. Outcomes were compared by use of propensity score adjustment to account for baseline differences between groups. Results: One hundred six patients with a PDA stent and 251 patients with a BT shunt were included. The groups differed in underlying anatomy (expected 2-ventricle circulation in 60% of PDA stents versus 45% of BT shunts; P =0.001) and presence of antegrade pulmonary blood flow (61% of PDA stents versus 38% of BT shunts; P <0.001). After propensity score adjustment, there was no difference in the hazard of the primary composite outcome of death or unplanned reintervention to treat cyanosis (hazard ratio, 0.8; 95% confidence interval [CI], 0.52–1.23; P =0.31). Other reinterventions were more common in the PDA stent group (hazard ratio, 29.8; 95% CI, 9.8–91.1; P <0.001). However, the PDA stent group had a lower adjusted intensive care unit length of stay (5.3 days [95% CI, 4.2–6.7] versus 9.19 days [95% CI, 7.9–10.6]; P <0.001), a lower risk of diuretic use at discharge (odds ratio, 0.4; 95% CI, 0.25–0.64; P <0.001) and procedural complications (odds ratio, 0.4; 95% CI, 0.2–0.77; P =0.006), and larger (152 mm 2 /m 2 [95% CI, 132–176] versus 125 mm 2 /m 2 [95% CI, 113–138]; P =0.029) and more symmetrical (symmetry index, 0.84 [95% CI, 0.8–0.89] versus 0.77 [95% CI, 0.75–0.8]; P =0.008] pulmonary arteries at the time of subsequent surgical repair or last follow-up. Conclusions: In this multicenter comparison of palliative PDA stent and BT shunt for infants with ductal-dependent pulmonary blood flow adjusted for differences in patient factors, there was no difference in the primary end point, death or unplanned reintervention to treat cyanosis. However, other markers of morbidity and pulmonary artery size favored the PDA stent group, supporting PDA stent as a reasonable alternative to BT shunt in select patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Harris, P. A., Taylor, R., Thielke, R., Payne, J., Gonzalez, N., & Conde, J. G. (2009) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2008.08.010 · Cited by 51,384
Nakata, S., Imai, Y., Takanashi, Y., Kurosawa, H., Tezuka, K., Nakazawa, M., Ando, M., & Takao, A. (1984) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)38300-x · Cited by 550
Gladman, G., McCrindle, B. W., Williams, W. G., Freedom, R. M., & Benson, L. N. (1997) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(97)70113-2 · Cited by 209
Sandoval, J. P., Chaturvedi, R. R., Benson, L. N., Morgan, G. J., Arsdell, G. V., Honjo, O., Caldarone, C. A., & Lee, K. (2016) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.116.003979 · Cited by 115
Early systemic-to-pulmonary artery shunt intervention in neonates with congenital heart disease
O’Connor, M. J., Ravishankar, C., Ballweg, J. A., Gillespie, M. J., Gaynor, J. W., Tabbutt, S., & Dominguez, T. E. (2011) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2010.10.033 · Cited by 94
Sivakumar, K., Bhagyavathy, A., Coelho, R., Radhakrishnan, S., & Krishnan, P. (2012) · Congenital Heart Disease · doi:10.1111/j.1747-0803.2012.00657.x · Cited by 39
Ödemiş, E., Haydın, S., Güzeltaş, A., Özyılmaz, İ., Bilici, M., & Bakır, İ. (2012) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezr258 · Cited by 35
Arterial duct stenting in low‐weight newborns with duct‐dependent pulmonary circulation
Santoro, G., Gaio, G., Castaldi, B., Palladino, M. T., Iacono, C., Russo, M. G., & Calabrò, R. (2011) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.23076 · Cited by 20
Cited by
Current outcomes and treatment of tetralogy of Fallot
van der Ven, J. P. G., van den Bosch, E., Bogers, A. J. C. C., & Helbing, W. A. (2019) · F1000Research · doi:10.12688/f1000research.17174.1 · Cited by 169
Metadata
- Authors
- Glatz, A. C., Petit, C. J., Goldstein, B. H., Kelleman, M. S., McCracken, C. E., McDonnell, A., Buckey, T., Mascio, C. E., Shashidharan, S., Ligon, R. A., Ao, J., Whiteside, W., Wallen, W. J., Metcalf, C. M., Aggarwal, V., Agrawal, H., & Qureshi, A. M.
- Venue
- Circulation
- Published
- 2018-02-06
- Volume
- 137
- Issue
- 6
- Pages
- 589-601
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2766100205
- Cited by
- 264
- References
- 8
- FWCI
- 10.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison Between Patent Ductus Arteriosus Stent and Modified Blalock-Taussig Shunt as Palliation for Infants With Ductal-Dependent Pulmonary Blood Flow: Insights From the Congenital Catheterization Research Collaborative. https://app.cochat.ai/papers/10.1161/circulationaha.117.029987
- The paper
- Glatz, A. C., Petit, C. J., Goldstein, B. H., Kelleman, M. S., McCracken, C. E., McDonnell, A., Buckey, T., Mascio, C. E., Shashidharan, S., Ligon, R. A., Ao, J., Whiteside, W., Wallen, W. J., Metcalf, C. M., Aggarwal, V., Agrawal, H., & Qureshi, A. M. (2018). Comparison Between Patent Ductus Arteriosus Stent and Modified Blalock-Taussig Shunt as Palliation for Infants With Ductal-Dependent Pulmonary Blood Flow: Insights From the Congenital Catheterization Research Collaborative. Circulation. https://doi.org/10.1161/circulationaha.117.029987
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.