The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Derivation and Validation of a Novel Right-Sided Heart Failure Model After Implantation of Continuous Flow Left Ventricular Assist Devices: The EUROMACS (European Registry for Patients with Mechanical Circulatory Support) Right-Sided Heart Failure Risk Score
Open accessAbstract
Background: The aim of the study was to derive and validate a novel risk score for early right-sided heart failure (RHF) after left ventricular assist device implantation. Methods: The EUROMACS (European Registry for Patients with Mechanical Circulatory Support) was used to identify adult patients undergoing continuous-flow left ventricular assist device implantation with mainstream devices. Eligible patients (n=2988) were randomly divided into derivation (n=2000) and validation (n=988) cohorts. The primary outcome was early (<30 days) severe postoperative RHF, defined as receiving short- or long-term right-sided circulatory support, continuous inotropic support for ≥14 days, or nitric oxide ventilation for ≥48 hours. The secondary outcome was all-cause mortality and length of stay in the intensive care unit. Covariates found to be associated with RHF (exploratory univariate P <0.10) were entered into a multivariable logistic regression model. A risk score was then generated using the relative magnitude of the exponential regression model coefficients of independent predictors at the last step after checking for collinearity, likelihood ratio test, c index, and clinical weight at each step. Results: A 9.5-point risk score incorporating 5 variables (Interagency Registry for Mechanically Assisted Circulatory Support class, use of multiple inotropes, severe right ventricular dysfunction on echocardiography, ratio of right atrial/pulmonary capillary wedge pressure, hemoglobin) was created. The mean scores in the derivation and validation cohorts were 2.7±1.9 and 2.6±2.0, respectively ( P =0.32). RHF in the derivation cohort occurred in 433 patients (21.7%) after left ventricular assist device implantation and was associated with a lower 1-year (53% versus 71%; P <0.001) and 2-year (45% versus 58%; P <0.001) survival compared with patients without RHF. RHF risk ranged from 11% (low risk score 0–2) to 43.1% (high risk score >4; P <0.0001). Median intensive care unit stay was 7 days (interquartile range, 4–15 days) versus 24 days (interquartile range, 14–38 days) in patients without versus with RHF, respectively ( P <0.001). The c index of the composite score was 0.70 in the derivation and 0.67 in the validation cohort. The EUROMACS-RHF risk score outperformed ( P <0.0001) previously published scores and known individual echocardiographic and hemodynamic markers of RHF. Conclusions: This novel EUROMACS-RHF risk score outperformed currently known risk scores and clinical predictors of early postoperative RHF. This novel score may be useful for tailored risk-based clinical assessment and management of patients with advanced HF evaluated for ventricular assist device therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validation of the Atherosclerotic Cardiovascular Disease Pooled Cohort Risk Equations
Muntner, P., Colantonio, L. D., Cushman, M., Goff, D. C., Howard, G., Howard, V. J., Kissela, B., Levitan, E. B., Lloyd-Jones, D. M., & Safford, M. M. (2014) · JAMA · doi:10.1001/jama.2014.2630 · Cited by 603
Lancellotti, P., Tribouilloy, C., Hagendorff, A., Moura, L., Popescu, B. A., Agricola, E., Monin, J. L., Pierard, L. A., Badano, L., Zamorano, J. L., et al. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq030 · Cited by 501
Cited by
Nicoara, A., Skubas, N., Ad, N., Finley, A., Hahn, R. T., Mahmood, F., Mankad, S., Nyman, C. B., Pagani, F., Porter, T. R., et al. (2020) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2020.03.002 · Cited by 264
Metadata
- Authors
- Soliman, O. I. I., Akin, S., Muslem, R., Boersma, E., Manintveld, O. C., Krabatsch, T., Gummert, J. F., de By, T. M. M. H., Bogers, A. J. J. C., Zijlstra, F., Mohacsi, P., & Caliskan, K.
- Venue
- Circulation
- Published
- 2018-02-27
- Volume
- 137
- Issue
- 9
- Pages
- 891-906
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2746466083
- Cited by
- 268
- References
- 2
- FWCI
- 9.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Derivation and Validation of a Novel Right-Sided Heart Failure Model After Implantation of Continuous Flow Left Ventricular Assist Devices: The EUROMACS (European Registry for Patients with Mechanical Circulatory Support) Right-Sided Heart Failure Risk Score. https://app.cochat.ai/papers/10.1161/circulationaha.117.030543
- The paper
- Soliman, O. I. I., Akin, S., Muslem, R., Boersma, E., Manintveld, O. C., Krabatsch, T., Gummert, J. F., de By, T. M. M. H., Bogers, A. J. J. C., Zijlstra, F., Mohacsi, P., & Caliskan, K. (2018). Derivation and Validation of a Novel Right-Sided Heart Failure Model After Implantation of Continuous Flow Left Ventricular Assist Devices: The EUROMACS (European Registry for Patients with Mechanical Circulatory Support) Right-Sided Heart Failure Risk Score. Circulation. https://doi.org/10.1161/circulationaha.117.030543
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.