CoChat

Rate, Timing, Correlates, and Outcomes of Hemodynamic Valve Deterioration After Bioprosthetic Surgical Aortic Valve Replacement

Salaun, Erwan, Mahjoub, Haïfa, Girerd, Nicolas, Dagenais, François, Voisine, Pierre, Mohammadi, Siamak, Yanagawa, Bobby, Kalavrouziotis, Dimitri, Juni, Peter, Verma, Subodh, Puri, Rishi, Coté, Nancy, Rodés-Cabau, Josep, Mathieu, Patrick, Clavel, Marie-Annick, Pibarot, Philippe · 2018 · Circulation
Cited by 119

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: The incidence of structural valve deterioration after bioprosthesis (BP) aortic valve replacement (AVR) established on the basis of reoperation may substantially underestimate the true incidence. The objective is to determine the rate, timing, correlates, and association between hemodynamic valve deterioration (HVD) and outcomes assessed by Doppler echocardiography after surgical BP AVR. Methods: A total of 1387 patients (62.2% male, 70.5±7.8 years of age) who underwent BP AVR were included in this retrospective study. Baseline echocardiography was performed at a median time of 4.1 (1.3–6.5) months after AVR. All patients had an echocardiographic follow-up ≥2 years after AVR (926 at least 5 years and 385 at least 10 years). HVD was defined by Doppler assessment as a ≥10 mm Hg increase in mean gradient or worsening of transprosthetic regurgitation ≥1/3 class. HVD was classified according to the timing after AVR: “very early,” during the first 2-years; “early,” between 2 and 5 years; “midterm,” between 5 and 10 years; and “long-term,” >10 years. Results: A total of 428 patients (30.9%) developed HVD. Among these patients, 52 (12.0%) were classified as “very early,” 129 (30.1%) as “early,” 158 (36.9%) as “midterm,” and 89 (20.8%) as “long-term” HVD. Factors independently associated with HVD occurring within the first 5 years after AVR were diabetes mellitus ( P =0.01), active smoking ( P =0.01), renal insufficiency ( P =0.01), baseline postoperative mean gradient ≥15 mm Hg ( P =0.04) or transprosthetic regurgitation ≥mild ( P =0.04), and type of BP (stented versus stentless, P =0.003). Factors associated with HVD occurring after the fifth year after AVR were female sex ( P =0.03), warfarin use ( P =0.007), and BP type ( P <0.001). HVD was independently associated with mortality (hazard ratio, 2.18; 95% CI, 1.86–2.57; P <0.001). Conclusions: HVD as identified by Doppler echocardiography occurred in one third of patients and was associated with a 2.2-fold higher adjusted mortality. Diabetes mellitus and renal insufficiency were associated with early HVD, whereas female sex, warfarin use, and stented BPs (versus stentless) were associated with late HVD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.118.035150

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 119

Metadata

Authors
Salaun, E., Mahjoub, H., Girerd, N., Dagenais, F., Voisine, P., Mohammadi, S., Yanagawa, B., Kalavrouziotis, D., Juni, P., Verma, S., Puri, R., Coté, N., Rodés-Cabau, J., Mathieu, P., Clavel, M.-A., & Pibarot, P.
Venue
Circulation
Published
2018-09-04
Volume
138
Issue
10
Pages
971-985
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2887478446
Cited by
119
References
3
FWCI
9.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rate, Timing, Correlates, and Outcomes of Hemodynamic Valve Deterioration After Bioprosthetic Surgical Aortic Valve Replacement. https://app.cochat.ai/papers/10.1161/circulationaha.118.035150
The paper
Salaun, E., Mahjoub, H., Girerd, N., Dagenais, F., Voisine, P., Mohammadi, S., Yanagawa, B., Kalavrouziotis, D., Juni, P., Verma, S., Puri, R., Coté, N., Rodés-Cabau, J., Mathieu, P., Clavel, M.-A., & Pibarot, P. (2018). Rate, Timing, Correlates, and Outcomes of Hemodynamic Valve Deterioration After Bioprosthetic Surgical Aortic Valve Replacement. Circulation. https://doi.org/10.1161/circulationaha.118.035150

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.