Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 181

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Cost-Effectiveness of Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Stenosis at Intermediate Risk: Results From the PARTNER 2 Trial

Open access
Baron, Suzanne J., Wang, Kaijun, House, John A., Magnuson, Elizabeth A., Reynolds, Matthew R., Makkar, Raj, Herrmann, Howard C., Kodali, Susheel, Thourani, Vinod H., Kapadia, Samir, Svensson, Lars, Mack, Michael J., Brown, David L., Russo, Mark J., Smith, Craig R., Webb, John, Miller, Craig, Leon, Martin B., Cohen, David J., On behalf of the PARTNER 2 Investigators·2019·Circulation

Abstract

Background: In patients with severe aortic stenosis (AS) at intermediate surgical risk, treatment with transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) results in similar rates of death or stroke at 2 years. Whether TAVR is cost-effective compared with SAVR for intermediate-risk patients remains uncertain. Methods: Between 2011 and 2014, 3110 intermediate-risk AS patients were treated with TAVR or SAVR in the PARTNER 2 trial (Placement of Aortic Transcatheter Valves 2). A total of 2032 patients were randomized to receive TAVR using the SAPIEN XT valve (XT-TAVR) or SAVR in the PARTNER 2A trial, whereas the PARTNER S3i registry included an additional 1078 patients treated with TAVR using the SAPIEN 3 valve (S3-TAVR), which offers a lower delivery profile and sealing skirt designed to reduce paravalvular regurgitation compared with XT-TAVR. Procedural costs were estimated using measured resource utilization. Other in-trial costs were assessed by linkage of trial data with Medicare claims (n=2333) or by linear regression models for unlinked patients (n=682). Health utilities were estimated using the EQ-5D at baseline and 1, 12, and 24 months. Using a Markov model informed by in-trial costs, utilities, and survival data, lifetime cost-effectiveness from the perspective of the US healthcare system was estimated in terms of cost per quality-adjusted life-year gained. Results: Although procedural costs were ≈$20 000 higher with TAVR than SAVR, total cost differences for the index hospitalization were only $2888 higher with XT-TAVR ( P =0.014) and were $4155 lower with S3-TAVR ( P <0.001) owing to reductions in length of stay with TAVR. Follow-up costs were significantly lower with XT-TAVR (Δ=−$9304; P <0.001) and S3-TAVR (Δ=−$11 377; P <0.001) than with SAVR. Over a lifetime horizon, TAVR was projected to lower total costs by $8000 to $10 000 and to increase quality-adjusted survival by 0.15 to 0.27 years. XT-TAVR and S3-TAVR were found to be economically dominant compared with SAVR in 84% and 97% of bootstrap replicates, respectively. Conclusions: Among intermediate-risk AS patients, TAVR is projected to be economically dominant from the perspective of the US healthcare system by providing both greater quality-adjusted life expectancy and lower long-term costs than SAVR. If long-term data demonstrate comparable late mortality with TAVR and SAVR, these findings suggest that TAVR might be the preferred treatment strategy for intermediate-risk AS patients based on both clinical and economic considerations. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT01314313.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.118.035236

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 181

Metadata

Authors
Baron, S. J., Wang, K., House, J. A., Magnuson, E. A., Reynolds, M. R., Makkar, R., Herrmann, H. C., Kodali, S., Thourani, V. H., Kapadia, S., Svensson, L., Mack, M. J., Brown, D. L., Russo, M. J., Smith, C. R., Webb, J., Miller, C., Leon, M. B., Cohen, D. J., & On behalf of the PARTNER 2 Investigators
Venue
Circulation
Published
2019-02-12
Volume
139
Issue
7
Pages
877-888
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2916705285
Cited by
181
References
5
FWCI
17.93
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cost-Effectiveness of Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Stenosis at Intermediate Risk: Results From the PARTNER 2 Trial. https://app.cochat.ai/papers/10.1161/circulationaha.118.035236
The paper
Baron, S. J., Wang, K., House, J. A., Magnuson, E. A., Reynolds, M. R., Makkar, R., Herrmann, H. C., Kodali, S., Thourani, V. H., Kapadia, S., Svensson, L., Mack, M. J., Brown, D. L., Russo, M. J., Smith, C. R., Webb, J., Miller, C., Leon, M. B., Cohen, D. J., & On behalf of the PARTNER 2 Investigators. (2019). Cost-Effectiveness of Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Stenosis at Intermediate Risk: Results From the PARTNER 2 Trial. Circulation. https://doi.org/10.1161/circulationaha.118.035236

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.