The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Aortic Stenosis and Small Aortic Annulus: Clinical Challenges and Current Therapeutic Alternatives
Abstract
The presence of a small aortic annulus poses a considerable challenge in the management of patients with severe aortic stenosis, especially in elderly women, where it is a very frequent finding. The optimal approach for treating these patients remains controversial, and several surgical strategies such as aortic root enlargement, supra-annular stented prosthetic valves, stentless bioprosthesis, and sutureless bioprostheses have been proposed to improve valve hemodynamics and clinical outcomes. More recently, transcatheter aortic valve replacement has emerged as a valid alternative for the treatment of aortic stenosis and excellent valve hemodynamic results have been observed among patients with a small aortic annulus. The purpose of this review is to provide an overview of the current definition, prevalence, and clinical impact of small aortic annulus in patients with aortic stenosis, and evaluate the different therapeutic strategies currently available to improve valve hemodynamics and outcomes in this population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Athappan, G., Patvardhan, E., Tuzcu, E. M., Svensson, L. G., Lemos, P. A., Fraccaro, C., Tarantini, G., Sinning, J.-M., Nickenig, G., Capodanno, D., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.047 · Cited by 782
Rodés-Cabau, J., Pibarot, P., Suri, R. M., Kodali, S., Thourani, V. H., Szeto, W. Y., Svensson, L. G., Dumont, E., Xu, K., Hahn, R. T., et al. (2014) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.114.001681 · Cited by 130
Self-citation
Cited by
2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Marin-Cuartas, M., Abreu, A., Adamo, M., Ajmone Marsan, N., Barili, F., Bonaros, N., Cosyns, B., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf194 · Cited by 1,072
Self-Expanding or Balloon-Expandable TAVR in Patients with a Small Aortic Annulus
Herrmann, H. C., Mehran, R., Blackman, D. J., Bailey, S., Möllmann, H., Abdel-Wahab, M., Ben Ali, W., Mahoney, P. D., Ruge, H., Wood, D. A., et al. (2024) · New England Journal of Medicine · doi:10.1056/nejmoa2312573 · Cited by 306
Springhetti, P., Abdoun, K., & Clavel, M.-A. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13144237 · Cited by 24
Metadata
- Authors
- Freitas-Ferraz, A. B., Tirado-Conte, G., Dagenais, F., Ruel, M., Al-Atassi, T., Dumont, E., Mohammadi, S., Bernier, M., Pibarot, P., & Rodés-Cabau, J.
- Venue
- Circulation
- Published
- 2019-06-04
- Volume
- 139
- Issue
- 23
- Pages
- 2685-2702
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2948708191
- Cited by
- 159
- References
- 3
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Aortic Stenosis and Small Aortic Annulus: Clinical Challenges and Current Therapeutic Alternatives. https://app.cochat.ai/papers/10.1161/circulationaha.118.038408
- The paper
- Freitas-Ferraz, A. B., Tirado-Conte, G., Dagenais, F., Ruel, M., Al-Atassi, T., Dumont, E., Mohammadi, S., Bernier, M., Pibarot, P., & Rodés-Cabau, J. (2019). Aortic Stenosis and Small Aortic Annulus: Clinical Challenges and Current Therapeutic Alternatives. Circulation. https://doi.org/10.1161/circulationaha.118.038408
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.