The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Replacement: A Propensity-Matched Comparison From the FRANCE-TAVI Registry
Open accessAbstract
Background: No randomized study powered to compare balloon expandable (BE) with self expanding (SE) transcatheter heart valves (THVs) on individual end points after transcatheter aortic valve replacement has been conducted to date. Methods: From January 2013 to December 2015, the FRANCE-TAVI nationwide registry (Registry of Aortic Valve Bioprostheses Established by Catheter) included 12 141 patients undergoing BE-THV (Edwards, n=8038) or SE-THV (Medtronic, n=4103) for treatment of native aortic stenosis. Long term mortality status was available in all patients (median 20 months; interquartile range, 14 to 30). Patients treated with BE-THV (n=3910) were successfully matched 1:1 with 3910 patients treated with SE-THV by using propensity score (25 clinical, anatomical, and procedural variables) and by date of the procedure (within 3 months). The first coprimary outcome was ≥ moderate occurrence of paravalvular regurgitation or in-hospital mortality, or both. The second coprimary outcome was 2-year all-cause mortality. Results: In propensity–matched analyses, the incidence of the first coprimary outcome was higher with SE-THV (19.8%) compared with BE-THV (11.9%; relative risk, 1.68 [95% CI, 1.46–1.91]; P <0.0001). Each component of the outcome was also higher in patients receiving SE-THV: ≥ moderate paravalvular regurgitation (15.5% versus 8.3%; relative risk, 1.90 [95% CI, 1.63–2.22]; P <0.0001) and in hospital mortality (5.6% versus 4.2%; relative risk, 1.34 [95% CI, 1.07–1.66]; P =0.01). During follow up, all cause mortality occurred in 899 patients treated with SE-THV (2-year mortality, 29.8%) and in 801 patients treated with BE-THV (2-year mortality, 26.6%; hazard ratio, 1.17 [95% CI, 1.06–1.29]; P =0.003). Similar results were found using inverse probability of treatment weighting using propensity score analysis. Conclusion: The present study suggests that use of SE-THV was associated with a higher risk of paravalvular regurgitation and higher in-hospital and 2-year mortality compared with use of BE-THV. These data strongly support the need for a randomized trial sufficiently powered to compare the latest generation of SE-THV and BE-THV. Clinical Trial Registration: https://www.clinicaltrials.gov . Unique identifier: NCT01777828.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Austin, P. C. (2011) · Multivariate Behavioral Research · doi:10.1080/00273171.2011.568786 · Cited by 12,242 · cited 1×
“20,21 As the primary analysis, propensity score was used to assemble well-balanced groups (propensity score–matched cohort) and, as a sensitivity analysis, propensity score was used to weight each subject by the inverse probability of treatment (stabilized inverse propensity score as weight) and…”
MethodTranscatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Austin, P. C. (2011) · Pharmaceutical Statistics · doi:10.1002/pst.433 · Cited by 3,949 · cited 1×
“22,23 Because of missing baseline data (range, 0% to 14%), leading to 24.5% of the study sample with at least 1 missing value among confounders included in propensity score calculation, treatment effect sizes were estimated using the multiple imputation method.”
MethodInfluentialPartial residuals for the proportional hazards regression model
SCHOENFELD, D. (1982) · Biometrika · doi:10.1093/biomet/69.1.239 · Cited by 3,111
A tutorial on propensity score estimation for multiple treatments using generalized boosted models
McCaffrey, D. F., Griffin, B. A., Almirall, D., Slaughter, M. E., Ramchand, R., & Burgette, L. F. (2013) · Statistics in Medicine · doi:10.1002/sim.5753 · Cited by 1,450 · cited 1×
“20,21 As the primary analysis, propensity score was used to assemble well-balanced groups (propensity score–matched cohort) and, as a sensitivity analysis, propensity score was used to weight each subject by the inverse probability of treatment (stabilized inverse propensity score as weight) and…”
MethodRegistry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, B., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114705 · Cited by 1,228
Self-citationA comparison of 12 algorithms for matching on the propensity score
Austin, P. C. (2014) · Statistics in Medicine · doi:10.1002/sim.6004 · Cited by 1,085
Popma, J. J., Adams, D. H., Reardon, M. J., Yakubov, S. J., Kleiman, N. S., Heimansohn, D., Hermiller, J., Hughes, G. C., Harrison, J. K., Coselli, J., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.556 · Cited by 1,040
Athappan, G., Patvardhan, E., Tuzcu, E. M., Svensson, L. G., Lemos, P. A., Fraccaro, C., Tarantini, G., Sinning, J.-M., Nickenig, G., Capodanno, D., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.047 · Cited by 782
Cited by
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000923 · Cited by 3,686
2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.11.018 · Cited by 1,982
2020 ACC/AHA guideline for the management of patients with valvular heart disease
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2021.04.002 · Cited by 279
Metadata
- Authors
- Van Belle, E., Vincent, F., Labreuche, J., Auffret, V., Debry, N., Lefèvre, T., Eltchaninoff, H., Manigold, T., Gilard, M., Verhoye, J.-P., Himbert, D., Koning, R., Collet, J.-P., Leprince, P., Teiger, E., Duhamel, A., Cosenza, A., Schurtz, G., Porouchani, S., Lattuca, B., Robin, E., Coisne, A., Modine, T., Richardson, M., Joly, P., Rioufol, G., Ghostine, S., Bar, O., Amabile, N., Champagnac, D., Ohlmann, P., Meneveau, N., Lhermusier, T., Leroux, L., Leclercq, F., Gandet, T., Pinaud, F., Cuisset, T., Motreff, P., Souteyrand, G., Iung, B., Folliguet, T., Commeau, P., Cayla, G., Bayet, G., Darremont, O., Spaulding, C., Le Breton, H., & Delhaye, C.
- Venue
- Circulation
- Published
- 2020-01-28
- Volume
- 141
- Issue
- 4
- Pages
- 243-259
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2988400654
- Cited by
- 171
- References
- 12
- FWCI
- 15.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Replacement: A Propensity-Matched Comparison From the FRANCE-TAVI Registry. https://app.cochat.ai/papers/10.1161/circulationaha.119.043785
- The paper
- Van Belle, E., Vincent, F., Labreuche, J., Auffret, V., Debry, N., Lefèvre, T., Eltchaninoff, H., Manigold, T., Gilard, M., Verhoye, J.-P., Himbert, D., Koning, R., Collet, J.-P., Leprince, P., Teiger, E., Duhamel, A., Cosenza, A., Schurtz, G., Porouchani, S., . . . Delhaye, C. (2020). Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Replacement: A Propensity-Matched Comparison From the FRANCE-TAVI Registry. Circulation. https://doi.org/10.1161/circulationaha.119.043785
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.