Impact of Sapien 3 Balloon-Expandable Versus Evolut R Self-Expandable Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis: Data From a Nationwide Analysis

Open access
Deharo, Pierre, Bisson, Arnaud, Herbert, Julien, Lacour, Thibaud, Saint Etienne, Christophe, Grammatico-Guillon, Leslie, Porto, Alizée, Collart, Frederic, Bourguignon, Thierry, Cuisset, Thomas, Fauchier, Laurent · 2020 · Circulation
Cited by 127

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Two competing transcatheter aortic valve replacement (TAVR) technologies are currently available. Head-to-head comparisons of the relative performances of these 2 devices have been published. However, long-term clinical outcome evaluation remains limited by the number of patients analyzed, in particular, for recent-generation devices. Methods: Based on the French administrative hospital-discharge database, the study collected information for all consecutive patients treated with a TAVR device commercialized in France between 2014 and 2018. Propensity score matching was used for the analysis of outcomes during follow-up. The objective of this study was to analyze the outcomes of TAVR according to Sapien 3 balloon-expandable (BE) versus Evolut R self-expanding TAVR technology at a nationwide level in France. Results: A total of 31 113 patients treated with either Sapien 3 BE or Evolut R self-expanding TAVR were found in the database. After matching on baseline characteristics, 20 918 patients were analyzed (10 459 in each group with BE or self-expanding valves). During follow-up (mean [SD], 358 [384]; median [interquartile range], 232 [10–599] days), BE TAVR was associated with a lower yearly incidence of all-cause death (relative risk, 0.88; corrected P =0.005), cardiovascular death (relative risk, 0.82; corrected P =0.002), and rehospitalization for heart failure (relative risk, 0.84; corrected P <0.0001). BE TAVR was also associated with lower rates of pacemaker implantation after the procedure (relative risk, 0.72; corrected P <0.0001). Conclusions: On the basis of the largest cohort available, we observed that Sapien 3 BE valves were associated with lower rates of all-cause death, cardiovascular death, rehospitalization for heart failure, and pacemaker implantation after a TAVR procedure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.119.043971

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Deharo, P., Bisson, A., Herbert, J., Lacour, T., Saint Etienne, C., Grammatico-Guillon, L., Porto, A., Collart, F., Bourguignon, T., Cuisset, T., & Fauchier, L.
Venue
Circulation
Published
2020-01-28
Volume
141
Issue
4
Pages
260-268
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W3005481265
Cited by
127
References
2
FWCI
12.88
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.