Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 204

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Stenosis

Open access
Vincent, Flavien, Ternacle, Julien, Denimal, Tom, Shen, Mylène, Redfors, Bjorn, Delhaye, Cédric, Simonato, Matheus, Debry, Nicolas, Verdier, Basile, Shahim, Bahira, Pamart, Thibault, Spillemaeker, Hugues, Schurtz, Guillaume, Pontana, François, Thourani, Vinod H., Pibarot, Philippe, Van Belle, Eric · 2021 · Circulation

Abstract

After 15 years of successive randomized, controlled trials, indications for transcatheter aortic valve replacement (TAVR) are rapidly expanding. In the coming years, this procedure could become the first line treatment for patients with a symptomatic severe aortic stenosis and a tricuspid aortic valve anatomy. However, randomized, controlled trials have excluded bicuspid aortic valve (BAV), which is the most frequent congenital heart disease occurring in 1% to 2% of the total population and representing at least 25% of patients 80 years of age or older referred for aortic valve replacement. The use of a less invasive transcatheter therapy in this elderly population became rapidly attractive, and approximately 10% of patients currently undergoing TAVR have a BAV. The U.S. Food and Drug Administration and the “European Conformity” have approved TAVR for low-risk patients regardless of the aortic valve anatomy whereas international guidelines recommend surgical replacement in BAV populations. Given this progressive expansion of TAVR toward younger and lower-risk patients, heart teams are encountering BAV patients more frequently, while the ability of this therapy to treat such a challenging anatomy remains uncertain. This review will address the singularity of BAV anatomy and associated technical challenges for the TAVR procedure. We will examine and summarize available clinical evidence and highlight critical knowledge gaps regarding TAVR utilization in BAV patients. We will provide a comprehensive overview of the role of computed tomography scans in the diagnosis, and classification of BAV and TAVR procedure planning. Overall, we will offer an integrated framework for understanding the current role of TAVR in the treatment of bicuspid aortic stenosis and for guiding physicians in clinical decision-making.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.120.048048

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 204

Metadata

Authors
Vincent, F., Ternacle, J., Denimal, T., Shen, M., Redfors, B., Delhaye, C., Simonato, M., Debry, N., Verdier, B., Shahim, B., Pamart, T., Spillemaeker, H., Schurtz, G., Pontana, F., Thourani, V. H., Pibarot, P., & Van Belle, E.
Venue
Circulation
Published
2021-03-09
Volume
143
Issue
10
Pages
1043-1061
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W3134791894
Cited by
204
References
4
FWCI
18.94
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.