Validating QT-Interval Measurement Using the Apple Watch ECG to Enable Remote Monitoring During the COVID-19 Pandemic
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
◼ electrocardiography ◼ long QT syndrome ◼ remote consultation ◼ telemedicine S creening and monitoring for QT prolongation when certain medications are initiated are routinely performed to avoid arrhythmic complications.However, the novel coronavirus disease 2019 (COVID-19) pandemic and its proposed treatments-including hydroxychloroquine and azithromycin, which are known to prolong the QT interval 1 -raise logistical and safety concerns with established QT monitoring strategies.Recently, the American College of Cardiology made recommendations for QT monitoring in outpatients with COVID-19 on hydroxychloroquine/azithromycin, suggesting that the use of direct-to-consumer mobile devices such as the Apple Watch 1-lead ECG could be considered in cases of resource constraints or quarantines. 2The Apple Watch ECG is cleared by the US Food and Drug Administration for detecting atrial fibrillation but has not been studied for QT monitoring.Lead I (the lead recorded by the Apple Watch) may be suboptimal for measuring this interval; however, other leads can be reproduced by placing the smartwatch on the left ankle or chest. 3We therefore sought to validate the use of the Apple Watch for QT measurement, including using nonstandard smartwatch positions, in an unselected outpatient population.Between December 2019 and January 2020, 100 consecutive patients in sinus rhythm were enrolled from outpatient or emergency departments.The study was approved by our institutional review committee, and the subjects gave informed consent.Standard 12-lead ECGs were performed, followed by smartwatch electrocardiographic recordings using the Apple Watch Series 4 (Apple Inc, Cupertino, CA).After a brief demonstration, patients recorded 30-second Apple Watch electrocardiographic equivalents of lead I (AW-I; watch on left wrist), lead II (AW-II; watch on left ankle), and a simulated lead V 6 (AW-LAT; watch on left lateral chest; Figure [A]).Using commercially available software (EP Calipers, EP studios Inc, Louisville, KY), a cardiologist measured 3 RR and QT intervals to calculate the corrected QT interval (QTc) using the Bazett formula (Figure [B]).A QTc >480 milliseconds was considered high risk.Agreement between the 12-lead and Apple Watch QTc measurements was calculated with the use of the median absolute error and Bland-Altman analyses.To measure interobserver variability, all AW-I QTc measurements were repeated by a second blinded cardiologist, and the intraclass correlation coefficient was calculated on the basis of a 2-way random absolute agreement model with single measurements.Agreement on whether a tracing was interpretable was assessed with the Cohen κ statistic.T-wave amplitude was measured to evaluate its association with QTc measurement accuracy.The mean age was 67±7 years; 59% were male; and 35% had diagnosed cardiac disease.Heart rates were similar on 12-lead and Apple Watch recordings (69±11 bpm versus 70±13 bpm, respectively; P=0.2, paired Student t test).QTc intervals ranged from 336 to 530 milliseconds on 12-lead ECGs.Eight patients were identified as high risk, all of whom were similarly identified by the smartwatch.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chung, E. H., & Guise, K. D. (2015) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2014.10.005 · Cited by 85
Castelletti, S., Dagradi, F., Goulene, K., Danza, A. I., Baldi, E., Stramba-Badiale, M., & Schwartz, P. J. (2018) · International Journal of Cardiology · doi:10.1016/j.ijcard.2018.03.097 · Cited by 63
Cited by
How to use digital devices to detect and manage arrhythmias: an EHRA practical guide
Svennberg, E., Tjong, F., Goette, A., Akoum, N., Di Biase, L., Bordachar, P., Boriani, G., Burri, H., Conte, G., Deharo, J. C., et al. (2022) · Europace · doi:10.1093/europace/euac038 · Cited by 261
Self-citationKhoshrounejad, F., Hamednia, M., Mehrjerd, A., Pichaghsaz, S., Jamalirad, H., Sargolzaei, M., Hoseini, B., & Aalaei, S. (2021) · Frontiers in Public Health · doi:10.3389/fpubh.2021.711762 · Cited by 174
Jensen, M. T., Treskes, R. W., Caiani, E. G., Casado-Arroyo, R., Cowie, M. R., Dilaveris, P., Duncker, D., Di Rienzo, M., Frederix, I., De Groot, N., et al. (2021) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztab011 · Cited by 93
Spaccarotella, C., Polimeni, A., Mancuso, C., Pelaia, G., Esposito, G., & Indolfi, C. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11061467 · Cited by 65
“More recently, we and others demonstrated that it is possible to assess QTc measurements with the Apple Watch [8,9] and even Brugada syndrome ECG patterns [10].”
BackgroundMethod
Metadata
- Authors
- Strik, M., Caillol, T., Ramirez, F. D., Abu-Alrub, S., Marchand, H., Welte, N., Ritter, P., Haïssaguerre, M., Ploux, S., & Bordachar, P.
- Venue
- Circulation
- Published
- 2020-07-28
- Volume
- 142
- Issue
- 4
- Pages
- 416-418
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W3032777011
- Cited by
- 96
- References
- 2
- FWCI
- 9.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.