Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 162

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Influence of Monitoring Strategy on Assessment of Ablation Success and Postablation Atrial Fibrillation Burden Assessment: Implications for Practice and Clinical Trial Design

Aguilar, Martin, Macle, Laurent, Deyell, Marc W., Yao, Robert, Hawkins, Nathaniel M., Khairy, Paul, Andrade, Jason G. · 2022 · Circulation

Abstract

Background: Various noninvasive intermittent rhythm monitoring strategies have been used to assess arrhythmia recurrences in trials evaluating pharmacological and invasive therapeutic interventions for atrial fibrillation (AF). We determined whether a frequency and duration of noninvasive rhythm monitoring could be identified that accurately detects arrhythmia recurrences and approximates the AF burden derived from continuous monitoring using an implantable cardiac monitor (ICM). Methods: The rhythm history of 346 patients enrolled in the CIRCA-DOSE trial (Cryoballoon Versus Contact-Force Irrigated Radiofrequency Catheter Ablation) was reconstructed. Using computer simulations, we evaluated event-free survival, sensitivity, negative predictive value, and AF burden of a range of noninvasive monitoring strategies, including those used in contemporary AF ablation trials. Results: A total of 126 290 monitoring days were included in the analysis. At 12 months, 164 patients experienced atrial arrhythmia recurrence as documented by the ICM (1-year event-free survival, 52.6%). Most noninvasive monitoring strategies used in AF ablation trials had poor sensitivity for detecting arrhythmia recurrence. Sensitivity increased with the intensity of monitoring, with serial (3) short-duration monitors (24-/48-hour ECG monitors) missing a substantial proportion of recurrences (sensitivity, 15.8% [95% CI, 8.9%–20.7%] and 24.5% [95% CI, 16.2%–30.6%], respectively). Serial (3) longer-term monitors (14-day ECG monitors) more closely approximated the gold standard ICM (sensitivity, 64.6% [95% CI, 53.6%–74.3%]). AF burden derived from short-duration monitors significantly overestimated the true AF burden in patients with recurrences. Increasing monitoring duration resulted in improved correlation and concordance between noninvasive estimates of the invasive AF burden ( R 2 = 0.85 and interclass correlation coefficient = 0.91 for serial [3] 14-day ECG monitors versus ICM). Conclusions: The observed rate of postablation atrial tachyarrhythmia recurrence is highly dependent on the arrhythmia monitoring strategy employed. Between-trial discrepancies in outcomes may reflect different monitoring protocols. On the basis of measures of agreement, serial long-term (7–14 day) intermittent monitors accumulating at least 28 days of annual monitoring provide estimates of AF burden comparable with ICM. However, ICMs outperform intermittent monitoring for arrhythmia detection, and should be considered the gold standard for clinical trials. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01913522.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.121.056109

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 162

Metadata

Authors
Aguilar, M., Macle, L., Deyell, M. W., Yao, R., Hawkins, N. M., Khairy, P., & Andrade, J. G.
Venue
Circulation
Published
2022-01-04
Volume
145
Issue
1
Pages
21-30
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W3215621588
Cited by
162
References
2
FWCI
11.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of Monitoring Strategy on Assessment of Ablation Success and Postablation Atrial Fibrillation Burden Assessment: Implications for Practice and Clinical Trial Design. https://app.cochat.ai/papers/10.1161/circulationaha.121.056109
The paper
Aguilar, M., Macle, L., Deyell, M. W., Yao, R., Hawkins, N. M., Khairy, P., & Andrade, J. G. (2022). Influence of Monitoring Strategy on Assessment of Ablation Success and Postablation Atrial Fibrillation Burden Assessment: Implications for Practice and Clinical Trial Design. Circulation. https://doi.org/10.1161/circulationaha.121.056109

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.