Pediatric ECG-Based Deep Learning to Predict Left Ventricular Dysfunction and Remodeling
Open accessAbstract
BACKGROUND: Artificial intelligence–enhanced ECG analysis shows promise to detect ventricular dysfunction and remodeling in adult populations. However, its application to pediatric populations remains underexplored. METHODS: A convolutional neural network was trained on paired ECG–echocardiograms (≤2 days apart) from patients ≤18 years of age without major congenital heart disease to detect human expert–classified greater than mild left ventricular (LV) dysfunction, hypertrophy, and dilation (individually and as a composite outcome). Model performance was evaluated on single ECG–echocardiogram pairs per patient at Boston Children’s Hospital and externally at Mount Sinai Hospital using area under the receiver operating characteristic curve (AUROC) and area under the precision-recall curve (AUPRC). RESULTS: The training cohort comprised 92 377 ECG–echocardiogram pairs (46 261 patients; median age, 8.2 years). Test groups included internal testing (12 631 patients; median age, 8.8 years; 4.6% composite outcomes), emergency department (2830 patients; median age, 7.7 years; 10.0% composite outcomes), and external validation (5088 patients; median age, 4.3 years; 6.1% composite outcomes) cohorts. Model performance was similar on internal test and emergency department cohorts, with model predictions of LV hypertrophy outperforming the pediatric cardiologist expert benchmark. Adding age and sex to the model added no benefit to model performance. When using quantitative outcome cutoffs, model performance was similar between internal testing (composite outcome: AUROC, 0.88, AUPRC, 0.43; LV dysfunction: AUROC, 0.92, AUPRC, 0.23; LV hypertrophy: AUROC, 0.88, AUPRC, 0.28; LV dilation: AUROC, 0.91, AUPRC, 0.47) and external validation (composite outcome: AUROC, 0.86, AUPRC, 0.39; LV dysfunction: AUROC, 0.94, AUPRC, 0.32; LV hypertrophy: AUROC, 0.84, AUPRC, 0.25; LV dilation: AUROC, 0.87, AUPRC, 0.33), with composite outcome negative predictive values of 99.0% and 99.2%, respectively. Saliency mapping highlighted ECG components that influenced model predictions (precordial QRS complexes for all outcomes; T waves for LV dysfunction). High-risk ECG features include lateral T-wave inversion (LV dysfunction), deep S waves in V1 and V2 and tall R waves in V6 (LV hypertrophy), and tall R waves in V4 through V6 (LV dilation). CONCLUSIONS: This externally validated algorithm shows promise to inexpensively screen for LV dysfunction and remodeling in children, which may facilitate improved access to care by democratizing the expertise of pediatric cardiologists.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 50 · Cited by 59
Research works printed but not linked: 1
- [37]37. Arnaout R, Curran L, Zhao Y, Levine JC, Chinn E and Moon-Grady AJ. An ensemble of neural networks provides expert-level prenatal detection of complex congenital heart disease. Nat Med. 2021;27:882-891. [PubMed: 33990806]
- Authors
- Mayourian, J., La Cava, W. G., Vaid, A., Nadkarni, G. N., Ghelani, S. J., Mannix, R., Geva, T., Dionne, A., Alexander, M. E., Duong, S. Q., & Triedman, J. K.
- Affiliations
- Boston Children's Hospital (US)
- Computational Health Informatics Program (W.G.L.C.), Boston Children’s Hospital, MA.
- Icahn School of Medicine at Mount Sinai (US)
- Corresponding author
- Triedman, John K.
- ORCID
- Venue
- Circulation
- Published
- 2024-03-19
- Volume
- 149
- Issue
- 12
- Pages
- 917-931
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- PMC
- PMC10948312
- OpenAlex
- W4391534311
- Cited by
- 59
- References
- 50
- Citations by year
- 2026: 23 · 2025: 25 · 2024: 10 · 2023: 1
- FWCI
- 17.38
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (4r00lm012926-03, 1s10od026880-01, 1s10od030463-01, R00-LM012926)
- U.S. National Library of Medicine (R00-LM012926)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (P50HD105351)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- left ventricular dysfunction, left ventricular remodeling, left ventricular hypertrophy, pediatric electrocardiography, convolutional neural networks, deep learning, external validation, emergency department patients, pediatric cardiology, non-invasive diagnosis
- MeSH terms
- Deep Learning, Adult, Artificial Intelligence, Child, Child, Preschool, Electrocardiography, Humans, Hypertrophy, Left Ventricular, Ventricular Dysfunction, Left
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review