The DOI matches its Crossref record.
Electroanatomic Substrate of Idiopathic Left Ventricular Tachycardia: Unidirectional Block and Macroreentry Within the Purkinje Network
Open accessAbstract
Background — An abnormal potential (retroPP) from the left posterior Purkinje network has been demonstrated during sinus rhythm (SR) in some patients with idiopathic left ventricular tachycardia (ILVT). We hypothesized that this potential can specifically be identified and be a critical substrate for ILVT. Methods and Results — In 9 patients with ILVT and 6 control patients who underwent mapping of the left ventricle during SR using 3-dimensional electroanatomic mapping, an area with retroPP was found within the posterior Purkinje fiber network only in patients with ILVT. The earliest and latest retroPP was 185.4±57.4 and 465.2±37.3 ms after Purkinje potential; in the other patient with ILVT, an entire left ventricle mapping demonstrated a slow conduction area and passive retrograde activation along the posterior fascicle during ILVT. ILVT was noninducible in 3 patients after SR mapping. Diastolic potentials critical for ILVT during ILVT coincided with the earliest retroPP during SR in 7 patients. Mechanical termination of ILVT occurred in 5 patients. A single radiofrequency pulse was applied at the site with mechanical translation in 5 patients and the site with diastolic potential in 2 patients, and 3 radiofrequency pulses were delivered to the site with the earliest retroPP in the other 3 patients without inducible ILVT after SR mapping. No ILVT was inducible during control stimulation, and none recurred during follow-up of 9.1±5.1 months. Conclusion — In patients with ILVT, abnormal retroPP within the posterior Purkinje fiber network is a common finding. The earliest retroPP critical for ILVT substrate can be used for guiding successful ablation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Self-citation(2015) · Europace · doi:10.1093/europace/euv319 · Cited by 1,592
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Multiple mechanisms of spiral wave breakup in a model of cardiac electrical activity
Fenton, F. H., Cherry, E. M., Hastings, H. M., & Evans, S. J. (2002) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.1504242 · Cited by 559
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Self-citation
Metadata
- Authors
- Ouyang, F., Cappato, R., Ernst, S., Goya, M., Volkmer, M., Hebe, J., Antz, M., Vogtmann, T., Schaumann, A., Fotuhi, P., Hoffmann-Riem, M., & Kuck, K.-H.
- Venue
- Circulation
- Published
- 2002-01-29
- Volume
- 105
- Issue
- 4
- Pages
- 462-469
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2168924615
- Cited by
- 196
- References
- 0
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electroanatomic Substrate of Idiopathic Left Ventricular Tachycardia: Unidirectional Block and Macroreentry Within the Purkinje Network. https://app.cochat.ai/papers/10.1161/hc0402.102663
- The paper
- Ouyang, F., Cappato, R., Ernst, S., Goya, M., Volkmer, M., Hebe, J., Antz, M., Vogtmann, T., Schaumann, A., Fotuhi, P., Hoffmann-Riem, M., & Kuck, K.-H. (2002). Electroanatomic Substrate of Idiopathic Left Ventricular Tachycardia: Unidirectional Block and Macroreentry Within the Purkinje Network. Circulation. https://doi.org/10.1161/hc0402.102663
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.