Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 227

The DOI matches its Crossref record.

Isthmus Characteristics of Reentrant Ventricular Tachycardia After Myocardial Infarction

Open access
de Chillou, Christian, Lacroix, Dominique, Klug, Didier, Magnin-Poull, Isabelle, Marquié, Christelle, Messier, Marc, Andronache, Marius, Kouakam, Claude, Sadoul, Nicolas, Chen, Jian, Aliot, Etienne, Kacet, Salem · 2002 · Circulation

Abstract

Background — The reentrant mechanism of postinfarct ventricular tachycardia (VT) has been documented by surgical mapping analysis, but little is known about postinfarct VT circuits and the characteristics of their related protected isthmus with the use of 3D catheter mapping systems. Methods and Results — A 3D electroanatomic mapping was performed in 21 patients with well-tolerated, postinfarct, sustained VT. In total, 33 episodes of tachycardia (mean cycle length 432±74 ms) were induced and mapped. Complete maps demonstrated macroreentrant circuits with 1 loop (n=8) or 2 loops (n=25) rotating around a protected isthmus bounded by 2 approximately parallel conduction barriers that consisted of a line of double potentials, a scar area, or the mitral annulus. A total of 26 critical isthmi were identified for the 33 VTs mapped, with the same isthmus being shared by 2 to 4 different tachycardic morphologies in 5 patients. On average, isthmi were 31±7 mm long (ranging from 18 to 41 mm) and 16±8 mm wide (ranging from 6 to 36 mm) and harbored diastolic electrograms. The isthmus axis was oriented parallel to the mitral annulus plane in perimitral circuits and perpendicular to the mitral annulus plane in all other circuits. Linear radiofrequency ablation performed across the most accessible part of the isthmus prevented the recurrence of tachycardia in 19 patients (90%) with a follow-up at 16±8 months. Conclusions — Detailed 3D electroanatomic mapping is helpful in reconstructing postinfarct VT circuits and in defining the characteristics of their related protected isthmi. The wide range of isthmus width values supports the need of linear radiofrequency lesions to eliminate the reentrant substrate of postinfarct VTs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hc0602.103675

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 227

Metadata

Authors
de Chillou, C., Lacroix, D., Klug, D., Magnin-Poull, I., Marquié, C., Messier, M., Andronache, M., Kouakam, C., Sadoul, N., Chen, J., Aliot, E., & Kacet, S.
Venue
Circulation
Published
2002-02-12
Volume
105
Issue
6
Pages
726-731
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2114434240
Cited by
227
References
0
FWCI
5.19
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Isthmus Characteristics of Reentrant Ventricular Tachycardia After Myocardial Infarction. https://app.cochat.ai/papers/10.1161/hc0602.103675
The paper
de Chillou, C., Lacroix, D., Klug, D., Magnin-Poull, I., Marquié, C., Messier, M., Andronache, M., Kouakam, C., Sadoul, N., Chen, J., Aliot, E., & Kacet, S. (2002). Isthmus Characteristics of Reentrant Ventricular Tachycardia After Myocardial Infarction. Circulation. https://doi.org/10.1161/hc0602.103675

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.