Value of Stress Myocardial Perfusion Single Photon Emission Computed Tomography in Patients With Normal Resting Electrocardiograms: An Evaluation of Incremental Prognostic Value and Cost-Effectiveness

Open access
Hachamovitch, Rory, Berman, Daniel S., Kiat, Hosen, Cohen, Ishac, Friedman, John D., Shaw, Leslee J.·2002·Circulation

Abstract

Background — The incremental value and cost-effectiveness of stress single photon emission computed tomography (SPECT) is of unclear added value over clinical and exercise treadmill testing data in patients with normal resting ECGs, a patient subset known to be at relatively lower risk. Methods and Results — We identified 3058 consecutive patients who underwent exercise dual isotope SPECT, who on follow-up (mean, 1.6±0.5 years; 3.6% lost to follow-up) were found to have 70 hard events (2.3% hard-event rate). Survival analysis used a Cox proportional hazards model, and cost-effectiveness was determined by the cost per hard event identified by strategies with versus without the use of SPECT. In this cohort, a normal study was associated with an exceedingly low hard-event rate (0.4% per year) that increased significantly as a function of the SPECT result. After adjusting for pre-SPECT information, exercise stress SPECT yielded incremental value for the prediction of hard events (χ 2 52 to 85, P <0.001) and significantly stratified patients. In patients with intermediate to high likelihood of coronary artery disease after exercise treadmill testing, a cost-effectiveness ratio of $25 134 per hard event identified and a cost of $5417 per reclassification of patient risk were found. Subset analyses revealed similar prognostic, and cost results were present in men, women, and patients with and without prior histories of coronary artery disease. Conclusions — Stress SPECT yields incremental prognostic value and enhanced risk stratification in patients with normal resting ECGs in a cost-effective manner. These findings are opposite those of previous studies examining anatomic end points in this same population and thus, if confirmed, have significant implications for patient management.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hc0702.103973

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 209

Metadata

Authors
Hachamovitch, R., Berman, D. S., Kiat, H., Cohen, I., Friedman, J. D., & Shaw, L. J.
Venue
Circulation
Published
2002-02-19
Volume
105
Issue
7
Pages
823-829
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2036611617
Cited by
209
References
0
FWCI
13.28
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Value of Stress Myocardial Perfusion Single Photon Emission Computed Tomography in Patients With Normal Resting Electrocardiograms: An Evaluation of Incremental Prognostic Value and Cost-Effectiveness. https://app.cochat.ai/papers/10.1161/hc0702.103973
The paper
Hachamovitch, R., Berman, D. S., Kiat, H., Cohen, I., Friedman, J. D., & Shaw, L. J. (2002). Value of Stress Myocardial Perfusion Single Photon Emission Computed Tomography in Patients With Normal Resting Electrocardiograms: An Evaluation of Incremental Prognostic Value and Cost-Effectiveness. Circulation. https://doi.org/10.1161/hc0702.103973

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.