CoChat

Macrophage Accumulation Associated With Rat Cardiac Allograft Rejection Detected by Magnetic Resonance Imaging With Ultrasmall Superparamagnetic Iron Oxide Particles

Kanno, Shinichi, Wu, Yi-Jen Lin, Lee, Paul C., Dodd, Stephen J., Williams, Mangay, Griffith, Bartley P., Ho, Chien · 2001 · Circulation
Cited by 156

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background — Acute cardiac allograft rejection continues to be the cause of graft loss and contributes to the morbidity and mortality after cardiac transplantation. In this study, we report a new method for detecting organ rejection in transplantation with an MR-based technique using dextran-coated ultrasmall superparamagnetic iron oxide (USPIO) particles. These particles (≈27 nm in diameter) are known to shorten relaxation times in MRI experiments. Methods and Results — A new rat model of heterotopic heart and lung transplantation has been developed for MRI experiments. Allotransplantations (DA→BN) were performed (n=8), with syngeneic transplantations (BN→BN) serving as controls (n=8). MR images were obtained with a gradient echo method. At postoperative day 7, allotransplants developed moderate rejection as determined histopathologically. A significant reduction in MR signal intensity was observed after USPIO injection into rats with allotransplanted hearts. Syngeneic transplants showed no differences in MR signal intensity before and after USPIO injections. After injection of USPIO particles at postoperative day 6, a group of allotransplanted rats was treated with cyclosporin A (3 mg/kg). Animals treated with cyclosporin A for 7 days showed no reduction in MR signal intensity after USPIO reinjection at day 14, whereas animals treated for 4 days showed a significant decrease in MR signal intensity in the transplanted hearts indicative of acute graft rejection. Pathological analysis of these animals revealed that dextran-coated USPIO particles were taken up by the infiltrating macrophages that accumulated within the rejecting cardiac graft. Conclusions — This MRI method offers promise as a noninvasive method for detecting transplant allograft rejection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hc3401.093148

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 156

Metadata

Authors
Kanno, S., Wu, Y.-J. L., Lee, P. C., Dodd, S. J., Williams, M., Griffith, B. P., & Ho, C.
Venue
Circulation
Published
2001-08-21
Volume
104
Issue
8
Pages
934-938
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2130578018
Cited by
156
References
1
FWCI
4.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Macrophage Accumulation Associated With Rat Cardiac Allograft Rejection Detected by Magnetic Resonance Imaging With Ultrasmall Superparamagnetic Iron Oxide Particles. https://app.cochat.ai/papers/10.1161/hc3401.093148
The paper
Kanno, S., Wu, Y.-J. L., Lee, P. C., Dodd, S. J., Williams, M., Griffith, B. P., & Ho, C. (2001). Macrophage Accumulation Associated With Rat Cardiac Allograft Rejection Detected by Magnetic Resonance Imaging With Ultrasmall Superparamagnetic Iron Oxide Particles. Circulation. https://doi.org/10.1161/hc3401.093148

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.