CoChat

α 4 β 1 Integrin Activation of L-Type Calcium Channels in Vascular Smooth Muscle Causes Arteriole Vasoconstriction

Waitkus-Edwards, Kelli R., Martinez-Lemus, Luis A., Wu, Xin, Trzeciakowski, Jerome P., Davis, Michael J., Davis, George E., Meininger, Gerald A. · 2002 · Circulation Research
Cited by 109

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A pathway for the regulation of vascular tone appears to involve coupling between integrins and extracellular matrix proteins or their fragments and the subsequent modulation of ion movement across the smooth muscle cell membrane. Here, we report that the activation of L-type voltage-activated Ca 2+ channels occurs through a novel interaction of α 4 β 1 integrin with peptides containing the Leu-Asp-Val (LDV) integrin–binding sequence, which is found in the CS-1 region of an alternately spliced fibronectin variant. Experiments were conducted on arterioles isolated from rat skeletal muscle. Arterioles exhibited sustained concentration-dependent vasoconstriction to LDV peptides but not to Leu-Glu-Val (LEV) control peptides. The constriction was associated with increased smooth muscle cell [Ca 2+ ] i , as measured by using fura 2. The response could be inhibited with a function-blocking anti–α 4 integrin antibody. Removal of the endothelium did not alter the vasoconstrictor response. Further experiments demonstrated that the vasoconstriction was abolished by the L-type Ca 2+ channel inhibitor nifedipine and the Src family kinase inhibitor PP2. In studies of isolated smooth muscle cells using whole-cell patch-clamp methods, the L-type current was enhanced by the LDV but not LEV peptide and was blocked by PP2 or antibodies to α 4 integrin. Collectively, these data indicate that activation of α 4 β 1 integrin leads to enhanced influx of Ca 2+ through L-type channels by activating a tyrosine kinase pathway, leading to vasoconstriction. Involvement of integrins in the modulation of vascular tone may be particularly important in vascular responses to mechanical signals, such as pressure and flow, and to tissue injury after damage to the extracellular matrix.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hh0402.105899

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 109

Metadata

Authors
Waitkus-Edwards, K. R., Martinez-Lemus, L. A., Wu, X., Trzeciakowski, J. P., Davis, M. J., Davis, G. E., & Meininger, G. A.
Venue
Circulation Research
Published
2002-03-08
Volume
90
Issue
4
Pages
473-480
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W1975609281
Cited by
109
References
1
FWCI
5.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.