Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 225

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Contribution of the 5-HT 1B Receptor to Hypoxia-Induced Pulmonary Hypertension: Converging Evidence Using 5-HT 1B -Receptor Knockout Mice and the 5-HT 1B/1D -Receptor Antagonist GR127935

Keegan, Alan, Morecroft, Ian, Smillie, Diane, Hicks, Martin N., MacLean, Margaret R.·2001·Circulation Research

Abstract

5-Hydroxytryptamine (5-HT) 1B receptors mediate contraction in human pulmonary arteries, and 5-HT 1B receptor-mediated contraction is enhanced in pulmonary arteries from hypoxic rats. Here we further examine the role of this receptor in the development of pulmonary hypertension (PHT) by examining (1) the effects of a 5-HT 1B/1D -receptor antagonist (GR127935) on hypoxia-induced PHT (CHPHT) in rats and (2) CHPHT in 5-HT 1B -receptor knockout mice. In rats, hypoxia increased right ventricular pressure and right ventricular hypertrophy and induced pulmonary vascular remodeling associated with an increase in pulmonary arterial wall thickness. GR127935 (3 mg · kg −1 · d −1 ) reduced all of these indices. 5-HT 1 -mediated contraction was enhanced in pulmonary arteries of the CHPHT rats. The effects of GR127935 on PHT indices were associated with an attenuation of the enhanced contractile responses to 5-HT and the 5-HT 1 -receptor agonist, 5-carboxamidotryptamine (5-CT), in isolated pulmonary arteries. In wild-type mice, hypoxia increased right ventricular hypertrophy, which was absent in 5-HT 1B -receptor knockout mice. Hypoxia increased pulmonary vascular remodeling in wild-type mice, and this was reduced in the 5-HT 1B -receptor knockout mice. Hypoxia increased 5-HT 1 -mediated contraction in pulmonary arteries from the wild-type mice and this was attenuated in the 5-HT 1B -receptor knockout mice. In conclusion, the 5-HT 1B receptor plays a role in the development of CHPHT. One possible mechanism may be via enhanced 5-HT 1 receptor-mediated contraction of the pulmonary arterial circulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hh2401.100426

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 225

Metadata

Authors
Keegan, A., Morecroft, I., Smillie, D., Hicks, M. N., & MacLean, M. R.
Venue
Circulation Research
Published
2001-12-07
Volume
89
Issue
12
Pages
1231-1239
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2023167197
Cited by
225
References
1
FWCI
4.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Contribution of the 5-HT 1B Receptor to Hypoxia-Induced Pulmonary Hypertension: Converging Evidence Using 5-HT 1B -Receptor Knockout Mice and the 5-HT 1B/1D -Receptor Antagonist GR127935. https://app.cochat.ai/papers/10.1161/hh2401.100426
The paper
Keegan, A., Morecroft, I., Smillie, D., Hicks, M. N., & MacLean, M. R. (2001). Contribution of the 5-HT 1B Receptor to Hypoxia-Induced Pulmonary Hypertension: Converging Evidence Using 5-HT 1B -Receptor Knockout Mice and the 5-HT 1B/1D -Receptor Antagonist GR127935. Circulation Research. https://doi.org/10.1161/hh2401.100426

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.