Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 346

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Magnetic Resonance Imaging Detection of Microbleeds Before Thrombolysis: An Emerging Application

Kidwell, Chelsea S., Saver, Jeffrey L., Villablanca, J. Pablo, Duckwiler, Gary, Fredieu, Andre, Gough, Kristi, Leary, Megan C., Starkman, Sidney, Gobin, Y. Pierre, Jahan, Reza, Vespa, Paul, Liebeskind, David S., Alger, Jeffry R., Vinuela, Fernando·2002·Stroke

Abstract

Background — Hemorrhagic transformation (HT) is a major complication of thrombolytic treatment for acute ischemic stroke. Although a history of prior intracerebral hemorrhage diagnosed by head CT is a contraindication to thrombolysis, there are no guidelines or data regarding evidence of prior asymptomatic microbleeds visualized with T2*-weighted magnetic resonance imaging (MRI). Methods — Pretreatment T2*-weighted MRI sequences were retrospectively analyzed in all patients receiving intra-arterial thrombolytic therapy and undergoing a pretreatment MRI at our institution. The frequency and location of prior microbleeds was determined and compared with the frequency and location of secondary HT after therapy. Results — Five of 41 patients undergoing MRI before receiving intra-arterial thrombolytic therapy demonstrated evidence of prior microbleeds on the pretreatment MRI studies. Major symptomatic hemorrhage occurred in 1 of 5 patients with microbleeds compared with 4 of 36 patients without. Only 1 patient in the entire 41-patient cohort experienced any HT outside the acute ischemic field. In this patient, the symptomatic hemorrhage occurred directly at the site of a prior microbleed, contralateral to the acute ischemic event. Conclusions — Old silent microbleeds, visualized with T2*-weighted MRI sequences, may be a marker of increased risk of HT in patients receiving thrombolytic therapy for acute ischemic stroke. Pretreatment screening of thrombolytic candidates with these MRI sequences may be useful in the future to identify these patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hs0102.101792

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 346

Metadata

Authors
Kidwell, C. S., Saver, J. L., Villablanca, J. P., Duckwiler, G., Fredieu, A., Gough, K., Leary, M. C., Starkman, S., Gobin, Y. P., Jahan, R., Vespa, P., Liebeskind, D. S., Alger, J. R., & Vinuela, F.
Venue
Stroke
Published
2002-01
Volume
33
Issue
1
Pages
95-98
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2171164712
Cited by
346
References
2
FWCI
18.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic Resonance Imaging Detection of Microbleeds Before Thrombolysis: An Emerging Application. https://app.cochat.ai/papers/10.1161/hs0102.101792
The paper
Kidwell, C. S., Saver, J. L., Villablanca, J. P., Duckwiler, G., Fredieu, A., Gough, K., Leary, M. C., Starkman, S., Gobin, Y. P., Jahan, R., Vespa, P., Liebeskind, D. S., Alger, J. R., & Vinuela, F. (2002). Magnetic Resonance Imaging Detection of Microbleeds Before Thrombolysis: An Emerging Application. Stroke. https://doi.org/10.1161/hs0102.101792

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.