Diurnal Variation in Blood Pressure and Arterial Stiffness in Chronic Kidney Disease: The Role of Endothelin-1
Abstract
Abstract—: Hypertension and arterial stiffness are important independent cardiovascular risk factors in chronic kidney disease (CKD) to which endothelin-1 (ET-1) contributes. Loss of nocturnal blood pressure (BP) dipping is associated with CKD progression, but there are no data on 24-hour arterial stiffness variation. We examined the 24-hour variation of BP, arterial stiffness, and the ET system in healthy volunteers and patients with CKD and the effects on these of ET receptor type A receptor antagonism (sitaxentan). There were nocturnal dips in systolic BP and diastolic BP and pulse wave velocity, our measure of arterial stiffness, in 15 controls (systolic BP, −3.2±4.8%, P <0.05; diastolic BP, −6.4±6.2%, P =0.001; pulse wave velocity, −5.8±5.2%, P <0.01) but not in 15 patients with CKD. In CKD, plasma ET-1 increased by 1.2±1.4 pg/mL from midday to midnight compared with healthy volunteers ( P <0.05). Urinary ET-1 did not change. In a randomized, double-blind, 3-way crossover study in 27 patients with CKD, 6-week treatment with placebo and nifedipine did not affect nocturnal dips in systolic BP or diastolic BP between baseline and week 6, whereas dipping was increased after 6-week sitaxentan treatment (baseline versus week 6, systolic BP: −7.0±6.2 versus −11.0±7.8 mm Hg, P <0.05; diastolic BP: −6.0±3.6 versus −8.3±5.1 mm Hg, P <0.05). There was no nocturnal dip in pulse pressure at baseline in the 3 phases of the study, whereas sitaxentan was linked to the development of a nocturnal dip in pulse pressure. In CKD, activation of the ET system seems to contribute not only to raised BP but also the loss of BP dipping. The clinical significance of these findings should be explored in future clinical trials. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifiers: NCT01770847 and NCT00810732.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Patients with chronic kidney disease commonly lack the normal greater than 10% dip in nighttime blood pressure compared with daytime blood pressure.
“Patients with chronic kidney disease commonly lack the normal greater than 10% dip in nighttime BP compared with daytime BP.”
From Role of the circadian system in cardiovascular disease (2018) · cites this paper as [78]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 53 · Cited by 54
Research works printed but not linked: 1
- Pickering TG, Shimbo D, Haas D. Ambulatory blood-pressure monitor- ing. N Engl J Med. 2006;354:2368-2374.
- Authors
- Dhaun, N., Moorhouse, R., MacIntyre, I. M., Melville, V., Oosthuyzen, W., Kimmitt, R. A., Brown, K. E., Kennedy, E. D., Goddard, J., & Webb, D. J.
- Affiliations
- Edinburgh Royal Infirmary (GB)
- Venue
- Hypertension
- Published
- 2014-08
- Volume
- 64
- Issue
- 2
- Pages
- 296-304
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2531308596
- Cited by
- 54
- References
- 53
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 4 · 2023: 1 · 2022: 3 · 2021: 3 · 2020: 7 · 2019: 5 · 2018: 9 · 2017: 4 · 2016: 4 · 2015: 7 · 2014: 2
- FWCI
- 3.87
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Hypertension (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Pfizer
- British Heart Foundation (FS/13/30/29994, PG/05/91)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Renal and Vascular Pathologies
- Keywords
- chronic kidney disease, nocturnal blood pressure dipping, diurnal blood pressure variation, arterial stiffness, endothelin-1, sitaxentan, pulse wave velocity, pulse pressure, nifedipine, cardiovascular risk
- MeSH terms
- Adult, Blood Pressure, Circadian Rhythm, Female, Humans, Isoxazoles, Male, Middle Aged, Thiophenes, Case-Control Studies, Endothelin-1, Renal Insufficiency, Chronic, Vascular Stiffness, Endothelin Receptor Antagonists
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review