CoChat

G-Protein–Coupled Receptor MrgD Is a Receptor for Angiotensin-(1–7) Involving Adenylyl Cyclase, cAMP, and Phosphokinase A

Open access
Tetzner, Anja, Gebolys, Kinga, Meinert, Christian, Klein, Sabine, Uhlich, Anja, Trebicka, Jonel, Villacañas, Óscar, Walther, Thomas · 2016 · Hypertension
Cited by 133

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Angiotensin (Ang)-(1–7) has cardiovascular protective effects and is the opponent of the often detrimental Ang II within the renin–angiotensin system. Although it is well accepted that the G-protein–coupled receptor Mas is a receptor for the heptapeptide, the lack in knowing initial signaling molecules stimulated by Ang-(1–7) prevented definitive characterization of ligand/receptor pharmacology as well as identification of further hypothesized receptors for the heptapeptide. The study aimed to identify a second messenger stimulated by Ang-(1–7) allowing confirmation as well as discovery of the heptapeptide’s receptors. Ang-(1–7) elevates cAMP concentration in primary cells, such as endothelial or mesangial cells. Using cAMP as readout in receptor-transfected human embryonic kidney (HEK293) cells, we provided pharmacological proof that Mas is a functional receptor for Ang-(1–7). Moreover, we identified the G-protein–coupled receptor MrgD as a second receptor for Ang-(1–7). Consequently, the heptapeptide failed to increase cAMP concentration in primary mesangial cells with genetic deficiency in both Mas and MrgD . Mice deficient in MrgD showed an impaired hemodynamic response after Ang-(1–7) administration. Furthermore, we excluded the Ang II type 2 receptor as a receptor for the heptapeptide but discovered that the Ang II type 2 blocker PD123319 can also block Mas and MrgD receptors. Our results lead to an expansion and partial revision of the renin–angiotensin system, by identifying a second receptor for Ang-(1–7), by excluding Ang II type 2 as a receptor for the heptapeptide, and by enforcing the revisit of such publications which concluded Ang II type 2 function by only using PD123319.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hypertensionaha.116.07572

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 133

Metadata

Authors
Tetzner, A., Gebolys, K., Meinert, C., Klein, S., Uhlich, A., Trebicka, J., Villacañas, Ó., & Walther, T.
Venue
Hypertension
Published
2016-07
Volume
68
Issue
1
Pages
185-194
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2401152555
Cited by
133
References
2
FWCI
12.70
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: G-Protein–Coupled Receptor MrgD Is a Receptor for Angiotensin-(1–7) Involving Adenylyl Cyclase, cAMP, and Phosphokinase A. https://app.cochat.ai/papers/10.1161/hypertensionaha.116.07572
The paper
Tetzner, A., Gebolys, K., Meinert, C., Klein, S., Uhlich, A., Trebicka, J., Villacañas, Ó., & Walther, T. (2016). G-Protein–Coupled Receptor MrgD Is a Receptor for Angiotensin-(1–7) Involving Adenylyl Cyclase, cAMP, and Phosphokinase A. Hypertension. https://doi.org/10.1161/hypertensionaha.116.07572

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.