CoChat

Subcutaneous Implantable Cardioverter Defibrillator in Patients With Hypertrophic Cardiomyopathy: An Initial Experience

Open access
Weinstock, Jonathan, Bader, Yousef H., Maron, Martin S., Rowin, Ethan J., Link, Mark S. · 2016 · Journal of the American Heart Association
Cited by 70

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: The subcutaneous implantable cardioverter defibrillator (S‐ ICD ) has been developed to avert risks associated with transvenous defibrillator leads. The technology is attractive for younger patients, such as those with hypertrophic cardiomyopathy (HCM). However, there are limited data on S‐ ICD use in HCM . Methods and Results: HCM patients identified at risk for sudden death were considered for S‐ ICD implantation. Patients were screened for potential oversensing by surface electrocardiography (ECG). At implant, defibrillation threshold ( DFT ) testing was performed at 65, 50, and 35 joules (J). Twenty‐seven patients were considered for S‐ ICD implantation, and after screening, 23 (85%) remained eligible. The presence of a bundle branch block was associated with screening failure, whereas elevated body mass index (BMI) showed a trend toward association. One patient passed screening at rest, but failed with an ECG obtained after exercise. At implant, the S‐ ICD terminated ventricular fibrillation ( VF ) with a 65J shock in all 15 implanted patients and a 50J shock was successful in 12 of 15. A 35J shock terminated VF in 10 of 12 patients. DFT failure at 50 J was associated with a higher BMI . There were no appropriate shocks after a median follow‐up of 17.5 (3–35) months, and 1 patient received an inappropriate shock attributable to a temporary reduction in QRS amplitude while bending forward, resulting in oversensing, despite successful screening. Conclusions: In a high‐risk HCM cohort without a pacing indication referred for consideration of an ICD , the majority were eligible for S‐ ICD . The S‐ ICD is effective at recognizing and terminating VF at implant with a wide safety margin.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/jaha.115.002488

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 70

Metadata

Authors
Weinstock, J., Bader, Y. H., Maron, M. S., Rowin, E. J., & Link, M. S.
Venue
Journal of the American Heart Association
Published
2016-02-23
Volume
5
Issue
2
ISSN
2047-9980 (ISSN-L)
OpenAlex
W2291916511
Cited by
70
References
2
FWCI
7.72
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Subcutaneous Implantable Cardioverter Defibrillator in Patients With Hypertrophic Cardiomyopathy: An Initial Experience. https://app.cochat.ai/papers/10.1161/jaha.115.002488
The paper
Weinstock, J., Bader, Y. H., Maron, M. S., Rowin, E. J., & Link, M. S. (2016). Subcutaneous Implantable Cardioverter Defibrillator in Patients With Hypertrophic Cardiomyopathy: An Initial Experience. Journal of the American Heart Association. https://doi.org/10.1161/jaha.115.002488

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.