The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Diagnostic Accuracy of Tissue Doppler Index E/è for Evaluating Left Ventricular Filling Pressure and Diastolic Dysfunction/Heart Failure With Preserved Ejection Fraction: A Systematic Review and Meta‐Analysis
Open accessAbstract
Background: Tissue Doppler index E/è is used clinically and in multidisciplinary research for estimation of left ventricular filling pressure ( LVFP ) and diastolic dysfunction ( DD )/heart failure with preserved ejection fraction ( HF p EF ). Its diagnostic accuracy is not well studied. Methods and Results: From the PubMed, Scopus, Embase, and Cochrane databases, we identified 24 studies reporting E/è and invasive LVFP in preserved EF (≥50%). In random‐effects models, E/è had poor to mediocre linear correlation with LVFP . Summary sensitivity and specificity (with 95% CIs ) for the American Society of Echocardiography–recommended E/è cutoffs (lateral, mean, and septal, respectively) to identify elevated LVFP was estimated by using hierarchical summary receiver operating characteristic analysis. Summary sensitivity was 30% (9–48%), 37% (13–61%), and 24% (6–46%), and summary specificity was 92% (82–100%), 91% (80–99%), and 98% (92–100%). Positive likelihood ratio ( LR +) was <5 for lateral and mean E/è. LR + was slightly >10 for septal E/è obtained from 4 studies (cumulative sample size <220). For excluding elevated LVFP , summary sensitivity for E/è (lateral, mean, and septal, respectively) was 64% (38–86%), 36% (3–74%), and 50% (14–81%), while summary specificity was 73% (54–89%), 83% (49–100%), and 89% (66–100%). Because of data set limitations, meaningful inference for identifying HF p EF by using E/è could not be drawn. With the use of quality assessment tool for diagnostic accuracy studies (Quality Assessment of Diagnostic Accuracy Studies questionnaire), we found substantial risks of bias and/or applicability. Conclusions: There is insufficient evidence to support that E/è can reliably estimate LVFP in preserved EF . The diagnostic accuracy of E/è to identify/exclude elevated LVFP and DD / HF p EF is limited and requires further validation in a well‐designed prospective clinical trial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Recommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351
Ommen, S. R., Nishimura, R. A., Appleton, C. P., Miller, F. A., Oh, J. K., Redfield, M. M., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.102.15.1788 · Cited by 2,790
Closing the Gap between Methodologists and End-Users: R as a Computational Back-End
Wallace, B. C., Dahabreh, I. J., Trikalinos, T. A., Lau, J., Trow, P., & Schmid, C. H. (2012) · Journal of Statistical Software · doi:10.18637/jss.v049.i05 · Cited by 1,125
Dokainish, H., Zoghbi, W. A., Lakkis, N. M., Al-Bakshy, F., Dhir, M., Quinones, M. A., & Nagueh, S. F. (2004) · Circulation · doi:10.1161/01.cir.0000127882.58426.7a · Cited by 465
Cited by
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab670 · Cited by 19,442
2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab368 · Cited by 13,344
Authors/Task Force Members:, McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., et al. (2022) · European Journal of Heart Failure · doi:10.1002/ejhf.2333 · Cited by 2,171
Pieske, B., Tschöpe, C., de Boer, R. A., Fraser, A. G., Anker, S. D., Donal, E., Edelmann, F., Fu, M., Guazzi, M., Lam, C. S. P., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz641 · Cited by 1,855
Galderisi, M., Cosyns, B., Edvardsen, T., Cardim, N., Delgado, V., Di Salvo, G., Donal, E., Sade, L. E., Ernande, L., Garbi, M., et al. (2017) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jex244 · Cited by 846
Metadata
- Authors
- Sharifov, O. F., Schiros, C. G., Aban, I., Denney, T. S., & Gupta, H.
- Venue
- Journal of the American Heart Association
- Published
- 2016-01-13
- Volume
- 5
- Issue
- 1
- ISSN
- 2047-9980 (ISSN-L)
- OpenAlex
- W2268647522
- Cited by
- 209
- References
- 6
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic Accuracy of Tissue Doppler Index E/è for Evaluating Left Ventricular Filling Pressure and Diastolic Dysfunction/Heart Failure With Preserved Ejection Fraction: A Systematic Review and Meta‐Analysis. https://app.cochat.ai/papers/10.1161/jaha.115.002530
- The paper
- Sharifov, O. F., Schiros, C. G., Aban, I., Denney, T. S., & Gupta, H. (2016). Diagnostic Accuracy of Tissue Doppler Index E/è for Evaluating Left Ventricular Filling Pressure and Diastolic Dysfunction/Heart Failure With Preserved Ejection Fraction: A Systematic Review and Meta‐Analysis. Journal of the American Heart Association. https://doi.org/10.1161/jaha.115.002530
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.