CoChat

Novel Bloodless Potassium Determination Using a Signal‐Processed Single‐Lead ECG

Open access
Attia, Zachi I., DeSimone, Christopher V., Dillon, John J., Sapir, Yehu, Somers, Virend K., Dugan, Jennifer L., Bruce, Charles J., Ackerman, Michael J., Asirvatham, Samuel J., Striemer, Bryan L., Bukartyk, Jan, Scott, Christopher G., Bennet, Kevin E., Ladewig, Dorothy J., Gilles, Emily J., Sadot, Dan, Geva, Amir B., Friedman, Paul A. · 2016 · Journal of the American Heart Association
Cited by 86

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: Hyper‐ and hypokalemia are clinically silent, common in patients with renal or cardiac disease, and are life threatening. A noninvasive, unobtrusive, blood‐free method for tracking potassium would be an important clinical advance. Methods and Results: Two groups of hemodialysis patients (development group, n=26; validation group, n=19) underwent high‐resolution digital ECG recordings and had 2 to 3 blood tests during dialysis. Using advanced signal processing, we developed a personalized regression model for each patient to noninvasively calculate potassium values during the second and third dialysis sessions using only the processed single‐channel ECG . In addition, by analyzing the entire development group's first‐visit data, we created a global model for all patients that was validated against subsequent sessions in the development group and in a separate validation group. This global model sought to predict potassium, based on the T wave characteristics, with no blood tests required. For the personalized model, we successfully calculated potassium values with an absolute error of 0.36±0.34 mmol/L (or 10% of the measured blood potassium). For the global model, potassium prediction was also accurate, with an absolute error of 0.44±0.47 mmol/L for the training group (or 11% of the measured blood potassium) and 0.5±0.42 for the validation set (or 12% of the measured blood potassium). Conclusions: The signal‐processed ECG derived from a single lead can be used to calculate potassium values with clinically meaningful resolution using a strategy that requires no blood tests. This enables a cost‐effective, noninvasive, unobtrusive strategy for potassium assessment that can be used during remote monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/jaha.115.002746

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 86

Metadata

Authors
Attia, Z. I., DeSimone, C. V., Dillon, J. J., Sapir, Y., Somers, V. K., Dugan, J. L., Bruce, C. J., Ackerman, M. J., Asirvatham, S. J., Striemer, B. L., Bukartyk, J., Scott, C. G., Bennet, K. E., Ladewig, D. J., Gilles, E. J., Sadot, D., Geva, A. B., & Friedman, P. A.
Venue
Journal of the American Heart Association
Published
2016-01-13
Volume
5
Issue
1
ISSN
2047-9980 (ISSN-L)
OpenAlex
W2294867897
Cited by
86
References
3
FWCI
3.49
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Novel Bloodless Potassium Determination Using a Signal‐Processed Single‐Lead ECG. https://app.cochat.ai/papers/10.1161/jaha.115.002746
The paper
Attia, Z. I., DeSimone, C. V., Dillon, J. J., Sapir, Y., Somers, V. K., Dugan, J. L., Bruce, C. J., Ackerman, M. J., Asirvatham, S. J., Striemer, B. L., Bukartyk, J., Scott, C. G., Bennet, K. E., Ladewig, D. J., Gilles, E. J., Sadot, D., Geva, A. B., & Friedman, P. A. (2016). Novel Bloodless Potassium Determination Using a Signal‐Processed Single‐Lead ECG. Journal of the American Heart Association. https://doi.org/10.1161/jaha.115.002746

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.