CoChat

Predictors of Mortality and Symptomatic Outcome of Patients With Low‐Flow Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement

Open access
Mangner, Norman, Stachel, Georg, Woitek, Felix, Haussig, Stephan, Schlotter, Florian, Höllriegel, Robert, Adam, Jennifer, Lindner, Anna, Mohr, Friedrich W., Schuler, Gerhard, Kiefer, Philipp, Leontyev, Sergey, Borger, Michael A., Thiele, Holger, Holzhey, David, Linke, Axel · 2018 · Journal of the American Heart Association
Cited by 64

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background: Impaired left ventricular (LV) ejection fraction is a common finding in patients with aortic stenosis and serves as a predictor of morbidity and mortality after transcatheter aortic valve replacement. However, conflicting data on the most accurate measure for LV function exist. We wanted to examine the impact of LV ejection fraction, mean pressure gradient, and stroke volume index on the outcome of patients treated by transcatheter aortic valve replacement. Methods and Results: Patients treated by transcatheter aortic valve replacement were primarily separated into normal flow ( NF ; stroke volume index >35 mL/m 2 ) and low flow ( LF ; stroke volume index ≤35 mL/m 2 ). Afterwards, patients were divided into 5 groups: “NF–high gradient,” “NF–low gradient” ( NF ‐ LG ), “LF–high gradient,” “paradoxical LF‐LG,” and “classic LF‐LG.” The 3‐year mortality was the primary end point. Of 1600 patients, 789 (49.3%) were diagnosed as having LF , which was characterized by a higher 30‐day ( P =0.041) and 3‐year ( P <0.001) mortality. LF was an independent predictor of all‐cause (hazard ratio, 1.29; 95% confidence interval, 1.03–1.62; P =0.03) and cardiovascular (hazard ratio, 1.37; 95% confidence interval, 1.06–1.77; P =0.016) mortality. Neither mean pressure gradient nor LV ejection fraction was an independent predictor of mortality. Patients with paradoxical LF‐LG (35.0%), classic LF‐LG (35.1%) and LF –high gradient (38.1%) had higher all‐cause mortality at 3 years compared with NF –high gradient (24.8%) and NF ‐ LG (27.9%) ( P =0.001). However, surviving patients showed a similar improvement in symptoms regardless of aortic stenosis entity. Conclusions: LF is a common finding within the aortic stenosis population and, in contrast to LV ejection fraction or mean pressure gradient, an independent predictor of all‐cause and cardiovascular mortality. Despite increased long‐term mortality, high procedural success and excellent functional improvement support transcatheter aortic valve replacement in patients with LF severe aortic stenosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/jaha.117.007977

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 64

Metadata

Authors
Mangner, N., Stachel, G., Woitek, F., Haussig, S., Schlotter, F., Höllriegel, R., Adam, J., Lindner, A., Mohr, F. W., Schuler, G., Kiefer, P., Leontyev, S., Borger, M. A., Thiele, H., Holzhey, D., & Linke, A.
Venue
Journal of the American Heart Association
Published
2018-04-17
Volume
7
Issue
8
ISSN
2047-9980 (ISSN-L)
OpenAlex
W2797384283
Cited by
64
References
5
FWCI
5.16
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.