Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 162

The DOI matches its Crossref record.

Comparison of 10 Different Magnetic Resonance Perfusion Imaging Processing Methods in Acute Ischemic Stroke: Effect on Lesion Size, Proportion of Patients With Diffusion/Perfusion Mismatch, Clinical Scores, and Radiologic Outcomes

Kane, Ingrid, Carpenter, Trevor, Chappell, Francesca, Rivers, Carly, Armitage, Paul, Sandercock, Peter, Wardlaw, Joanna·2007·Stroke

Abstract

Background and Purpose— Several methods are available to assess the magnetic resonance perfusion lesion in acute ischemic stroke. We tested 10 of these to compare perfusion lesion sizes and to assess the relation to clinical scores and final infarct extent. Methods— We recruited patients with acute ischemic stroke, performed diffusion- and perfusion-weighted imaging, and recorded stroke severity at baseline, final infarct size on T2-weighted imaging at ≥1 month, and Rankin Scale score at 3 months. We calculated 10 perfusion parameters (6 of mean transit time, MTT; 3 of cerebral blood flow; 1 of cerebral blood volume; 7 relative and 3 quantitative), measured the perfusion-weighted imaging lesion and diffusion/perfusion mismatch volumes, and compared each with clinical and radiologic outcomes. Results— Among 32 patients, the median perfusion lesion volume varied from 0 to 14 882 voxels ( P <0.0001); the proportion of patients with mismatch varied from 9% to 72% ( P <0.05), depending on the perfusion parameter. Five measures of relative MTT were associated with baseline National Institutes of Health Stroke Scale score; 1 (arrival time fitted) was also associated with clinical outcome. Final infarct size was most strongly associated with MTT measures, including arrival time fitted. There was no advantage of quantitative perfusion measures and no relation between mismatch presence/absence and infarct expansion with any of the 10 perfusion measures. Conclusions— Perfusion lesion size differs markedly depending on the parameter calculated. Relative perfusion parameters performed as well as quantitative ones. Some parameters (mainly representing MTT measures) were correlated with clinical scores; others were correlated with final infarct size; and arrival time fitted was correlated with both. These findings should be validated in other datasets. A consensus is required on which perfusion measurement and processing methods should be used.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/strokeaha.107.483842

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 162

Metadata

Authors
Kane, I., Carpenter, T., Chappell, F., Rivers, C., Armitage, P., Sandercock, P., & Wardlaw, J.
Venue
Stroke
Published
2007-12
Volume
38
Issue
12
Pages
3158-3164
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2135043868
Cited by
162
References
0
FWCI
11.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of 10 Different Magnetic Resonance Perfusion Imaging Processing Methods in Acute Ischemic Stroke: Effect on Lesion Size, Proportion of Patients With Diffusion/Perfusion Mismatch, Clinical Scores, and Radiologic Outcomes. https://app.cochat.ai/papers/10.1161/strokeaha.107.483842
The paper
Kane, I., Carpenter, T., Chappell, F., Rivers, C., Armitage, P., Sandercock, P., & Wardlaw, J. (2007). Comparison of 10 Different Magnetic Resonance Perfusion Imaging Processing Methods in Acute Ischemic Stroke: Effect on Lesion Size, Proportion of Patients With Diffusion/Perfusion Mismatch, Clinical Scores, and Radiologic Outcomes. Stroke. https://doi.org/10.1161/strokeaha.107.483842

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.