Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 206

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Continuous Measurement of Autoregulation by Spontaneous Fluctuations in Cerebral Perfusion Pressure: Comparison of 3 Methods

Open access
Brady, Ken M., Lee, Jennifer K., Kibler, Kathleen K., Easley, R. Blaine, Koehler, Raymond C., Shaffner, Donald H. · 2008 · Stroke

Abstract

Background and Purpose— Clinical application of continuous autoregulation monitoring would benefit from a comparison of curves generated by online monitoring with standard autoregulation curves in animal models. We characterized the accuracy of 3 continuous monitors of autoregulation in a piglet model of hypotension. Methods— Piglets 5 to10 days old with intracranial pressure (ICP) at naïve or elevated (20 mm Hg) levels had gradual arterial hypotension induced by a balloon catheter in the inferior vena cava. Elevated ICP was maintained by a continuous infusion of artificial cerebrospinal fluid. Three indices of autoregulation were simultaneously and continuously calculated. A moving, linear Pearson’s coefficient between spontaneous slow waves of cerebral perfusion pressure and slow waves of laser-Doppler flux or cortical oxygenation rendered the laser-Doppler index and cerebral-oximetry index, respectively. Similar correlation between slow waves of arterial blood pressure and ICP rendered the pressure-reactivity index. The lower limit of autoregulation was determined directly for each animal by plotting laser-Doppler cortical red blood cell flux as a function of cerebral perfusion pressure. Receiver-operator characteristics were determined for the 3 indices. Results— The areas under the receiver-operator characteristics curves for discriminating the individual lower limit of autoregulation at low and high ICP were 0.89 and 0.85 for the laser-Doppler index, 0.89 and 0.84 for the cerebral-oximetry index, and 0.79 and 0.79 for the pressure-reactivity index. The pressure-reactivity index performed equally well at low and high ICPs. Conclusions— Continuous monitoring of autoregulation by spontaneous slow waves of cerebral perfusion pressure can accurately detect loss of autoregulation due to hypotension in piglets by all 3 modalities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/strokeaha.108.514877

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 206

Metadata

Authors
Brady, K. M., Lee, J. K., Kibler, K. K., Easley, R. B., Koehler, R. C., & Shaffner, D. H.
Venue
Stroke
Published
2008-09
Volume
39
Issue
9
Pages
2531-2537
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2134928333
Cited by
206
References
1
FWCI
3.34
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous Measurement of Autoregulation by Spontaneous Fluctuations in Cerebral Perfusion Pressure: Comparison of 3 Methods. https://app.cochat.ai/papers/10.1161/strokeaha.108.514877
The paper
Brady, K. M., Lee, J. K., Kibler, K. K., Easley, R. B., Koehler, R. C., & Shaffner, D. H. (2008). Continuous Measurement of Autoregulation by Spontaneous Fluctuations in Cerebral Perfusion Pressure: Comparison of 3 Methods. Stroke. https://doi.org/10.1161/strokeaha.108.514877

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.