The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
The Pediatric Stroke Outcome Measure: A Validation and Reliability Study
Open accessAbstract
Background and Purpose—: The Pediatric Stroke Outcome Measure (PSOM) is an objective, disease-specific outcome measure containing 115 test items suitable for newborn to adult ages. The PSOM measures neurological deficit and function across 5 subscales: right sensorimotor, left sensorimotor, language production, language comprehension, and cognitive/behavior yielding a final 10-point deficit score. The goal of this study was to examine PSOM construct validity in measuring neurological outcome in pediatric stroke survivors and interrater reliability (IRR) for both prospective and retrospective scoring. Methods—: For construct validity, PSOM subscale scores were correlated with scores on standardized neuropsychological measures matched by functional domain. We assessed IRR by comparing same-day “live” PSOM scores from 2 independent raters in 10 children (prospective IRR) and by comparing PSOM scores estimated from medical dictations across 5 raters in another 10 children (retrospective IRR). Results—: We analyzed PSOM scores from 203 children with ischemic stroke. PSOM subscales show good construct validity (ρ=0.2–0.4; P <0.05). PSOM subscale scores of normal/abnormal demonstrate strong agreement for domain-matched neuropsychology scores (alternative chance-corrected statistic=0.4–0.8). IRR was excellent with the 2 prospective raters' scores in almost perfect agreement (intraclass correlation coefficient, 0.93; 95% CI, 0.76–0.98). Retrospective IRR demonstrated strong agreement with an intraclass correlation coefficient of 0.77 (95% CI, 0.56–0.92). Conclusions—: The PSOM is a valid and reliable outcome measure for pediatric stroke. It is useful for retrospective scoring from health records and prospective serial longitudinal outcome assessments and is ideally suited for prospective clinical trials in pediatric stroke.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
Achenbach, T. M., & Ruffle, T. M. (2000) · Pediatrics in Review · doi:10.1542/pir.21-8-265 · Cited by 1,285
Interpreting the magnitudes of correlation coefficients.
Hemphill, J. F. (2003) · American Psychologist · doi:10.1037/0003-066x.58.1.78 · Cited by 1,237
Clinics in Developmental Medicine
(2013) · The Imitation of Gestures · doi:10.1016/b978-1-4831-9649-7.50021-9 · Cited by 1,142
Cerebral Sinovenous Thrombosis in Children
deVeber, G., Andrew, M., Adams, C., Bjornson, B., Booth, F., Buckley, D. J., Camfield, C. S., David, M., Humphreys, P., Langevin, P., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200108093450604 · Cited by 1,139
Self-citationClinical interpretation and use of stroke scales
Kasner, S. E. (2006) · The Lancet Neurology · doi:10.1016/s1474-4422(06)70495-1 · Cited by 934
Lynch, J. K., Hirtz, D. G., DeVeber, G., & Nelson, K. B. (2002) · Pediatrics · doi:10.1542/peds.109.1.116 · Cited by 645
Self-citationNeurologic Outcome in Survivors of Childhood Arterial Ischemic Stroke and Sinovenous Thrombosis
deVeber, G. A., MacGregor, D., Curtis, R., & Mayank, S. (2000) · Journal of Child Neurology · doi:10.1177/088307380001500508 · Cited by 636
Self-citationKwon, S., Hartzema, A. G., Duncan, P. W., & Min-Lai, S. (2004) · Stroke · doi:10.1161/01.str.0000119385.56094.32 · Cited by 319
Golomb, M. R., Fullerton, H. J., Nowak-Gottl, U., & deVeber, G. (2009) · Stroke · doi:10.1161/strokeaha.108.521203 · Cited by 304
Self-citation
Cited by
Geocadin, R. G., Callaway, C. W., Fink, E. L., Golan, E., Greer, D. M., Ko, N. U., Lang, E., Licht, D. J., Marino, B. S., McNair, N. D., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000702 · Cited by 428
Risk factor analysis of cerebral white matter hyperintensities in children with sickle cell disease
van der Land, V., Mutsaerts, H. J. M. M., Engelen, M., Heijboer, H., Roest, M., Hollestelle, M. J., Kuijpers, T. W., Nederkoorn, P. J., Cnossen, M. H., Majoie, C. B. L. M., et al. (2016) · British Journal of Haematology · doi:10.1111/bjh.13819 · Cited by 30
Metadata
- Authors
- Kitchen, L., Westmacott, R., Friefeld, S., MacGregor, D., Curtis, R., Allen, A., Yau, I., Askalan, R., Moharir, M., Domi, T., & deVeber, G.
- Venue
- Stroke
- Published
- 2012-06
- Volume
- 43
- Issue
- 6
- Pages
- 1602-1608
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2083261663
- Cited by
- 271
- References
- 37
- FWCI
- 13.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Pediatric Stroke Outcome Measure: A Validation and Reliability Study. https://app.cochat.ai/papers/10.1161/strokeaha.111.639583
- The paper
- Kitchen, L., Westmacott, R., Friefeld, S., MacGregor, D., Curtis, R., Allen, A., Yau, I., Askalan, R., Moharir, M., Domi, T., & deVeber, G. (2012). The Pediatric Stroke Outcome Measure: A Validation and Reliability Study. Stroke. https://doi.org/10.1161/strokeaha.111.639583
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.