Comparison of Flow Diversion and Coiling in Large Unruptured Intracranial Saccular Aneurysms
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Background and Purpose—: Flow diversion has emerged as an important tool for the management of intracranial aneurysms. The purpose of this study was to compare flow diversion and traditional embolization strategies in terms of safety, efficacy, and clinical outcomes in patients with unruptured, large saccular aneurysms (≥10 mm). Methods—: Forty patients treated with the Pipeline Embolization Device (PED) were matched in a 1:3 fashion with 120 patients treated with coiling based on patient age and aneurysm size. Fusiform and anterior communicating artery aneurysms were eliminated from the analysis. Procedural complications, angiographic results, and clinical outcomes were analyzed and compared. Results—: There were no differences between the 2 groups in terms of patient age, sex, aneurysm size, and aneurysm location. The rate of procedure-related complications did not differ between the PED (7.5%) and the coil group (7.5%; P =1). At the latest follow-up, a significantly higher proportion of aneurysms treated with PED (86%) achieved complete obliteration compared with coiled aneurysms (41%; P <0.001). In multivariable analysis, coiling was an independent predictor of nonocclusion. Retreatment was necessary in fewer patients in the PED group (2.8%) than the coil group (37%; P <0.001). A similar proportion of patients attained a favorable outcome (modified Rankin Scale, 0–2) in the PED group (92%) and in the coil group (94%; P =0.8). Conclusions—: The PED provides higher aneurysm occlusion rates than coiling, with no additional morbidity and similar clinical outcomes. These findings suggest that the PED might be a preferred treatment option for large unruptured saccular aneurysms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
PRACTICAL STATISTICS FOR MEDICAL RESEARCH
Ludbrook, J. (1991) · Australian and New Zealand Journal of Surgery · doi:10.1111/j.1445-2197.1991.tb00019.x · Cited by 1,213
Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial
Becske, T., Kallmes, D. F., Saatci, I., McDougall, C. G., Szikora, I., Lanzino, G., Moran, C. J., Woo, H. H., Lopes, D. K., Berez, A. L., et al. (2013) · Radiology · doi:10.1148/radiol.13120099 · Cited by 1,108
Endovascular Treatment of Intracranial Aneurysms With Flow Diverters: A Meta-Analysis
Brinjikji, W., Murad, M. H., Lanzino, G., Cloft, H. J., & Kallmes, D. F. (2013) · Stroke · doi:10.1161/strokeaha.112.678151 · Cited by 900 · cited 1×
“A recent meta-analysis of 29 studies, including 1451 patients with 1654 aneurysms, found that the rate of procedurerelated morbidity and mortality with flow diverters was 5% and 4%, respectively.(17) The authors concluded that the risk of procedure-related morbidity and mortality is not negligible and should be taken…”
BackgroundThe Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial
Nelson, P. K., Lylyk, P., Szikora, I., Wetzel, S. G., Wanke, I., & Fiorella, D. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2421 · Cited by 843
Kulcsár, Z., Houdart, E., Bonafé, A., Parker, G., Millar, J., Goddard, A. J. P., Renowden, S., Gál, G., Turowski, B., Mitchell, K., et al. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2370 · Cited by 521
Saatci, I., Yavuz, K., Ozer, C., Geyik, S., & Cekirge, H. S. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3246 · Cited by 368 · cited 1×
“Elsewhere, however, the morbidity rate associated with the PED was found to be negligible.(8,10) As such, Saatci et al(10) reported remarkably low rates of mortality (0.”
BackgroundCrobeddu, E., Lanzino, G. S., Kallmes, D. F., & Cloft, H. J. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2958 · Cited by 123
Single Center Experience With Pipeline Stent
Chitale, R. V., Gonzalez, L. F., Randazzo, C. G., Dumont, A. S., Tjoumakaris, S. I., Rosenwasser, R. H., Chalouhi, N., Gordon, D., & Jabbour, P. M. (2012) · Neurosurgery · doi:10.1227/neu.0b013e318260fe86 · Cited by 95
Self-citationCrobeddu, E., Lanzino, G. S., Kallmes, D. F., & Cloft, H. J. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3032 · Cited by 93 · cited 1×
“The use of balloon and stent technology was shown to improve treatment durability but results remain suboptimal.(23)”
Background
Cited by
Endovascular Microrobotics for Neurointervention
Santiago-Dieppa, D. R., & Friend, J. (2024) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060523-010720 · Cited by 12
Metadata
- Authors
- Chalouhi, N., Tjoumakaris, S., Starke, R. M., Gonzalez, L. F., Randazzo, C., Hasan, D., McMahon, J. F., Singhal, S., Moukarzel, L. A., Dumont, A. S., Rosenwasser, R., & Jabbour, P.
- Venue
- Stroke
- Published
- 2013-08
- Volume
- 44
- Issue
- 8
- Pages
- 2150-2154
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2166587773
- Cited by
- 248
- References
- 11
- FWCI
- 17.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.