The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Six-Minute Magnetic Resonance Imaging Protocol for Evaluation of Acute Ischemic Stroke: Pushing the Boundaries
Open accessAbstract
Background and Purpose—: If magnetic resonance imaging (MRI) is to compete with computed tomography for evaluation of patients with acute ischemic stroke, there is a need for further improvements in acquisition speed. Methods—: Inclusion criteria for this prospective, single institutional study were symptoms of acute ischemic stroke within 24 hours onset, National Institutes of Health Stroke Scale ≥3, and absence of MRI contraindications. A combination of echo-planar imaging (EPI) and a parallel acquisition technique were used on a 3T magnetic resonance (MR) scanner to accelerate the acquisition time. Image analysis was performed independently by 2 neuroradiologists. Results—: A total of 62 patients met inclusion criteria. A repeat MRI scan was performed in 22 patients resulting in a total of 84 MRIs available for analysis. Diagnostic image quality was achieved in 100% of diffusion-weighted imaging, 100% EPI-fluid attenuation inversion recovery imaging, 98% EPI-gradient recalled echo, 90% neck MR angiography and 96% of brain MR angiography, and 94% of dynamic susceptibility contrast perfusion scans with interobserver agreements ( k ) ranging from 0.64 to 0.84. Fifty-nine patients (95%) had acute infarction. There was good interobserver agreement for EPI-fluid attenuation inversion recovery imaging findings ( k =0.78; 95% confidence interval, 0.66–0.87) and for detection of mismatch classification using dynamic susceptibility contrast-Tmax ( k =0.92; 95% confidence interval, 0.87–0.94). Thirteen acute intracranial hemorrhages were detected on EPI-gradient recalled echo by both observers. A total of 68 and 72 segmental arterial stenoses were detected on contrast-enhanced MR angiography of the neck and brain with k =0.93, 95% confidence interval, 0.84 to 0.96 and 0.87, 95% confidence interval, 0.80 to 0.90, respectively. Conclusions—: A 6-minute multimodal MR protocol with good diagnostic quality is feasible for the evaluation of patients with acute ischemic stroke and can result in significant reduction in scan time rivaling that of the multimodal computed tomographic protocol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid Stenosis
(1991) · New England Journal of Medicine · doi:10.1056/nejm199108153250701 · Cited by 8,368
Cited by
Endovascular stent thrombectomy: the new standard of care for large vessel ischaemic stroke
Campbell, B. C. V., Donnan, G. A., Lees, K. R., Hacke, W., Khatri, P., Hill, M. D., Goyal, M., Mitchell, P. J., Saver, J. L., Diener, H.-C., et al. (2015) · The Lancet Neurology · doi:10.1016/s1474-4422(15)00140-4 · Cited by 313
Review of Perfusion Imaging in Acute Ischemic Stroke: From Time to Tissue
Demeestere, J., Wouters, A., Christensen, S., Lemmens, R., & Lansberg, M. G. (2020) · Stroke · doi:10.1161/strokeaha.119.028337 · Cited by 302
Collateral Circulation in Ischemic Stroke: Assessment Tools and Therapeutic Strategies
Bang, O. Y., Goyal, M., & Liebeskind, D. S. (2015) · Stroke · doi:10.1161/strokeaha.115.010508 · Cited by 277
Metadata
- Authors
- Nael, K., Khan, R., Choudhary, G., Meshksar, A., Villablanca, P., Tay, J., Drake, K., Coull, B. M., & Kidwell, C. S.
- Venue
- Stroke
- Published
- 2014-07
- Volume
- 45
- Issue
- 7
- Pages
- 1985-1991
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2117130359
- Cited by
- 173
- References
- 1
- FWCI
- 10.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.