Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 225

The DOI matches its Crossref record.

Plaque Echolucency and Stroke Risk in Asymptomatic Carotid Stenosis: A Systematic Review and Meta-Analysis

Open access
Gupta, Ajay, Kesavabhotla, Kartik, Baradaran, Hediyeh, Kamel, Hooman, Pandya, Ankur, Giambrone, Ashley E., Wright, Drew, Pain, Kevin J., Mtui, Edward E., Suri, Jasjit S., Sanelli, Pina C., Mushlin, Alvin I.·2015·Stroke

Abstract

Background and Purpose—: Ultrasonographic plaque echolucency has been studied as a stroke risk marker in carotid atherosclerotic disease. We performed a systematic review and meta-analysis to summarize the association between ultrasound-determined carotid plaque echolucency and future ipsilateral stroke risk. Methods—: We searched the medical literature for studies evaluating the association between carotid plaque echolucency and future stroke in asymptomatic patients. We included prospective observational studies with stroke outcome ascertainment after baseline carotid plaque echolucency assessment. We performed a meta-analysis and assessed study heterogeneity and publication bias. We also performed subgroup analyses limited to patients with stenosis ≥50%, studies in which plaque echolucency was determined via subjective visual interpretation, studies with a relatively lower risk of bias, and studies published after the year 2000. Results—: We analyzed data from 7 studies on 7557 subjects with a mean follow-up of 37.2 months. We found a significant positive relationship between predominantly echolucent (compared with predominantly echogenic) plaques and the risk of future ipsilateral stroke across all stenosis severities (0% to 99%; relative risk, 2.31; 95% confidence interval, 1.58–3.39; P <0.001) and in subjects with ≥50% stenosis (relative risk, 2.61; 95% confidence interval, 1.47–4.63; P =0.001). A statistically significant increased relative risk for future stroke was preserved in all additional subgroup analyses. No statistically significant heterogeneity or publication bias was present in any of the meta-analyses. Conclusions—: The presence of ultrasound-determined carotid plaque echolucency provides predictive information in asymptomatic carotid artery stenosis beyond luminal stenosis. However, the magnitude of the increased risk is not sufficient on its own to iden tify patients likely to benefit from surgical revascularization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/strokeaha.114.006091

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 225

Metadata

Authors
Gupta, A., Kesavabhotla, K., Baradaran, H., Kamel, H., Pandya, A., Giambrone, A. E., Wright, D., Pain, K. J., Mtui, E. E., Suri, J. S., Sanelli, P. C., & Mushlin, A. I.
Venue
Stroke
Published
2015-01
Volume
46
Issue
1
Pages
91-97
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2123796398
Cited by
225
References
0
FWCI
11.63
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Plaque Echolucency and Stroke Risk in Asymptomatic Carotid Stenosis: A Systematic Review and Meta-Analysis. https://app.cochat.ai/papers/10.1161/strokeaha.114.006091
The paper
Gupta, A., Kesavabhotla, K., Baradaran, H., Kamel, H., Pandya, A., Giambrone, A. E., Wright, D., Pain, K. J., Mtui, E. E., Suri, J. S., Sanelli, P. C., & Mushlin, A. I. (2015). Plaque Echolucency and Stroke Risk in Asymptomatic Carotid Stenosis: A Systematic Review and Meta-Analysis. Stroke. https://doi.org/10.1161/strokeaha.114.006091

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.