Magnetic Resonance Imaging in Experimental Stroke and Comparison With Histology: Systematic Review and Meta-Analysis
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Background and Purpose—: Because the new era of preclinical stroke research demands improvements in validity and generalizability of findings, moving from single site to multicenter studies could be pivotal. However, the conduct of magnetic resonance imaging (MRI) in stroke remains ill-defined. We sought to assess the variability in the use of MRI for evaluating lesions post stroke and to examine the possibility as an alternative to gold standard histology for measuring the infarct size. Methods—: We identified animal studies of ischemic stroke reporting lesion sizes using MRI. We assessed the degree of heterogeneity and reporting of scanning protocols, postprocessing methods, study design characteristics, and study quality. Studies performing histological evaluation of infarct size were further selected to compare with corresponding MRI using meta-regression. Results—: Fifty-four articles undertaking a total of 78 different MRI scanning protocols met the inclusion criteria. T 2 -weighted imaging was most frequently used (83% of the studies), followed by diffusion-weighted imaging (43%). Reporting of the imaging parameters was adequate, but heterogeneity between studies was high. Twelve studies assessed the infarct size using both MRI and histology at corresponding time points, with T 2 -weighted imaging–based treatment effect having a significant positive correlation with histology ( ; P <0.001). Conclusions—: Guidelines for standardized use and reporting of MRI in preclinical stroke are urgently needed. T 2 -weighted imaging could be used as an effective in vivo alternative to histology for estimating treatment effects based on the extent of infarction; however, additional studies are needed to explore the effect of individual parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
VEGF enhances angiogenesis and promotes blood–brain barrier leakage in the ischemic brain
Zhang, Z. G., Zhang, L., Jiang, Q., Zhang, R., Davies, K., Powers, C., Bruggen, N. V., & Chopp, M. (2000) · Journal of Clinical Investigation · doi:10.1172/jci9369 · Cited by 1,296
A call for transparent reporting to optimize the predictive value of preclinical research
Landis, S. C., Amara, S. G., Asadullah, K., Austin, C. P., Blumenstein, R., Bradley, E. W., Crystal, R. G., Darnell, R. B., Ferrante, R. J., Fillit, H., et al. (2012) · Nature · doi:10.1038/nature11556 · Cited by 1,196 · cited 2×
“Mouse: 2/10 (20) 5 (5) Mouse: 0/1 (0) N/G (N/G)”
Self-citationHarbord, R. M., & Higgins, J. P. T. (2008) · The Stata Journal: Promoting communications on statistics and Stata · doi:10.1177/1536867x0800800403 · Cited by 897
Good Laboratory Practice: Preventing Introduction of Bias at the Bench
Macleod, M. R., Fisher, M., O'Collins, V., Sena, E. S., Dirnagl, U., Bath, P. M. W., Buchan, A., van der Worp, H. B., Traystman, R., Minematsu, K., et al. (2009) · Stroke · doi:10.1161/strokeaha.108.525386 · Cited by 331
Self-citationMacleod, M. R., van der Worp, H. B., Sena, E. S., Howells, D. W., Dirnagl, U., & Donnan, G. A. (2008) · Stroke · doi:10.1161/strokeaha.108.515957 · Cited by 319
Self-citationMacrae, I. (2011) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2011.01398.x · Cited by 274 · cited 1×
“Scan duration, min 7/45 (16) Rat: 5/34 (15) 1.”
Koistinaho, M., Kettunen, M. I., Goldsteins, G., Keinänen, R., Salminen, A., Ort, M., Bures, J., Liu, D., Kauppinen, R. A., Higgins, L. S., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.032670899 · Cited by 159
Koistinaho, M., Malm, T. M., Kettunen, M. I., Goldsteins, G., Starckx, S., Kauppinen, R. A., Opdenakker, G., & Koistinaho, J. (2005) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600040 · Cited by 120 · cited 3×
“Diffusion gradient strength, G, mT/m N/A N/A N/A 6/23 (26) Rat: 5/22 (23) 0–152 (80)*”
Li, L., Jiang, Q., Ding, G., Zhang, L., Zhang, Z. G., Li, Q., Panda, S., Kapke, A., Lu, M., Ewing, J. R., et al. (2009) · Stroke · doi:10.1161/strokeaha.108.527713 · Cited by 67
Cited by
A manifesto for reproducible science
Munafò, M. R., Nosek, B. A., Bishop, D. V. M., Button, K. S., Chambers, C. D., Percie du Sert, N., Simonsohn, U., Wagenmakers, E.-J., Ware, J. J., & Ioannidis, J. P. A. (2017) · Nature Human Behaviour · doi:10.1038/s41562-016-0021 · Cited by 3,397
A survey of methods for 3D histology reconstruction
Pichat, J., Iglesias, J. E., Yousry, T., Ourselin, S., & Modat, M. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.02.004 · Cited by 207
“However, improving it becomes vain if similar attention is not also directed towards ensuring consistent, quality input data within and across institutions (Lin and Shi, 2015; Milidonis et al., 2015; Traboulsee et al., 2016).”
BackgroundAtlas registration for edema-corrected MRI lesion volume in mouse stroke models
Koch, S., Mueller, S., Foddis, M., Bienert, T., von Elverfeldt, D., Knab, F., Farr, T. D., Bernard, R., Dopatka, M., Rex, A., et al. (2019) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x17726635 · Cited by 74
Metadata
- Authors
- Milidonis, X., Marshall, I., Macleod, M. R., & Sena, E. S.
- Venue
- Stroke
- Published
- 2015-03
- Volume
- 46
- Issue
- 3
- Pages
- 843-851
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2155100785
- Cited by
- 42
- References
- 9
- FWCI
- 3.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Resonance Imaging in Experimental Stroke and Comparison With Histology: Systematic Review and Meta-Analysis. https://app.cochat.ai/papers/10.1161/strokeaha.114.007560
- The paper
- Milidonis, X., Marshall, I., Macleod, M. R., & Sena, E. S. (2015). Magnetic Resonance Imaging in Experimental Stroke and Comparison With Histology: Systematic Review and Meta-Analysis. Stroke. https://doi.org/10.1161/strokeaha.114.007560
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.