The DOI matches its Crossref record.
Comparison of Perfusion CT Software to Predict the Final Infarct Volume After Thrombectomy
Open accessAbstract
Background and Purpose—: Computed tomographic perfusion represents an interesting physiological imaging modality to select patients for reperfusion therapy in acute ischemic stroke. The purpose of our study was to determine the accuracy of different commercial perfusion CT software packages (Philips (A), Siemens (B), and RAPID (C)) to predict the final infarct volume (FIV) after mechanical thrombectomy. Methods—: Single-institutional computed tomographic perfusion data from 147 mechanically recanalized acute ischemic stroke patients were postprocessed. Ischemic core and FIV were compared about thrombolysis in cerebral infarction (TICI) score and time interval to reperfusion. FIV was measured at follow-up imaging between days 1 and 8 after stroke. Results—: In 118 successfully recanalized patients (TICI 2b/3), a moderately to strongly positive correlation was observed between ischemic core and FIV. The highest accuracy and best correlation are shown in early and fully recanalized patients (Pearson r for A=0.42, B=0.64, and C=0.83; P <0.001). Bland–Altman plots and boxplots demonstrate smaller ranges in package C than in A and B. Significant differences were found between the packages about over- and underestimation of the ischemic core. Package A, compared with B and C, estimated more than twice as many patients with a malignant stroke profile ( P <0.001). Package C best predicted hypoperfusion volume in nonsuccessfully recanalized patients. Conclusions—: Our study demonstrates best accuracy and approximation between the results of a fully automated software (RAPID) and FIV, especially in early and fully recanalized patients. Furthermore, this software package overestimated the FIV to a significantly lower degree and estimated a malignant mismatch profile less often than other software.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bertog, S. C., Sievert, K., Grunwald, I. Q., Sharma, A., Hornung, M., Kühn, A. L., Vaskelyte, L., Hofmann, I., Gafoor, S., Reinartz, M., et al. (2022) · Interventional Cardiology · doi:10.1002/9781119697367.ch71 · Cited by 356
Murray, N. M., Unberath, M., Hager, G. D., & Hui, F. K. (2020) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2019-015135 · Cited by 308
Review of Perfusion Imaging in Acute Ischemic Stroke: From Time to Tissue
Demeestere, J., Wouters, A., Christensen, S., Lemmens, R., & Lansberg, M. G. (2020) · Stroke · doi:10.1161/strokeaha.119.028337 · Cited by 302
Ko, S.-B., Park, H.-K., Kim, B. M., Heo, J. H., Rha, J.-H., Kwon, S. U., Kim, J. S., Lee, B.-C., Suh, S. H., Jung, C., et al. (2019) · Journal of Stroke · doi:10.5853/jos.2019.00024 · Cited by 63
Metadata
- Authors
- Austein, F., Riedel, C., Kerby, T., Meyne, J., Binder, A., Lindner, T., Huhndorf, M., Wodarg, F., & Jansen, O.
- Venue
- Stroke
- Published
- 2016-09
- Volume
- 47
- Issue
- 9
- Pages
- 2311-2317
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2489968831
- Cited by
- 231
- References
- 0
- FWCI
- 13.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Perfusion CT Software to Predict the Final Infarct Volume After Thrombectomy. https://app.cochat.ai/papers/10.1161/strokeaha.116.013147
- The paper
- Austein, F., Riedel, C., Kerby, T., Meyne, J., Binder, A., Lindner, T., Huhndorf, M., Wodarg, F., & Jansen, O. (2016). Comparison of Perfusion CT Software to Predict the Final Infarct Volume After Thrombectomy. Stroke. https://doi.org/10.1161/strokeaha.116.013147
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.