Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 231

The DOI matches its Crossref record.

Comparison of Perfusion CT Software to Predict the Final Infarct Volume After Thrombectomy

Open access
Austein, Friederike, Riedel, Christian, Kerby, Tina, Meyne, Johannes, Binder, Andreas, Lindner, Thomas, Huhndorf, Monika, Wodarg, Fritz, Jansen, Olav·2016·Stroke

Abstract

Background and Purpose—: Computed tomographic perfusion represents an interesting physiological imaging modality to select patients for reperfusion therapy in acute ischemic stroke. The purpose of our study was to determine the accuracy of different commercial perfusion CT software packages (Philips (A), Siemens (B), and RAPID (C)) to predict the final infarct volume (FIV) after mechanical thrombectomy. Methods—: Single-institutional computed tomographic perfusion data from 147 mechanically recanalized acute ischemic stroke patients were postprocessed. Ischemic core and FIV were compared about thrombolysis in cerebral infarction (TICI) score and time interval to reperfusion. FIV was measured at follow-up imaging between days 1 and 8 after stroke. Results—: In 118 successfully recanalized patients (TICI 2b/3), a moderately to strongly positive correlation was observed between ischemic core and FIV. The highest accuracy and best correlation are shown in early and fully recanalized patients (Pearson r for A=0.42, B=0.64, and C=0.83; P <0.001). Bland–Altman plots and boxplots demonstrate smaller ranges in package C than in A and B. Significant differences were found between the packages about over- and underestimation of the ischemic core. Package A, compared with B and C, estimated more than twice as many patients with a malignant stroke profile ( P <0.001). Package C best predicted hypoperfusion volume in nonsuccessfully recanalized patients. Conclusions—: Our study demonstrates best accuracy and approximation between the results of a fully automated software (RAPID) and FIV, especially in early and fully recanalized patients. Furthermore, this software package overestimated the FIV to a significantly lower degree and estimated a malignant mismatch profile less often than other software.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/strokeaha.116.013147

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 231

Metadata

Authors
Austein, F., Riedel, C., Kerby, T., Meyne, J., Binder, A., Lindner, T., Huhndorf, M., Wodarg, F., & Jansen, O.
Venue
Stroke
Published
2016-09
Volume
47
Issue
9
Pages
2311-2317
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2489968831
Cited by
231
References
0
FWCI
13.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Perfusion CT Software to Predict the Final Infarct Volume After Thrombectomy. https://app.cochat.ai/papers/10.1161/strokeaha.116.013147
The paper
Austein, F., Riedel, C., Kerby, T., Meyne, J., Binder, A., Lindner, T., Huhndorf, M., Wodarg, F., & Jansen, O. (2016). Comparison of Perfusion CT Software to Predict the Final Infarct Volume After Thrombectomy. Stroke. https://doi.org/10.1161/strokeaha.116.013147

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.