CoChat

Training for Walking Efficiency With a Wearable Hip-Assist Robot in Patients With Stroke: A Pilot Randomized Controlled Trial

Open access
Lee, Hwang-Jae, Lee, Su-Hyun, Seo, Keehong, Lee, Minhyung, Chang, Won Hyuk, Choi, Byung-Ok, Ryu, Gyu-Ha, Kim, Yun-Hee · 2019 · Stroke
Cited by 116

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background and Purpose—: The purpose of this study was to investigate the effects of gait training with a newly developed wearable hip-assist robot on locomotor function and efficiency in patients with chronic stroke. Methods—: Twenty-eight patients with stroke with hemiparesis were initially enrolled, and 26 patients completed the randomized controlled trial (14 in the experimental and 12 in the control groups). The experimental group participated in a gait training program over a total of 10 sessions, including 5 treadmill sessions and 5 over-ground gait training sessions while wearing a hip-assist robot, the Gait Enhancing and Motivating System (GEMS, Samsung Advanced Institute of Technology, Suwon, Republic of Korea). The control group received gait training without Gait Enhancing and Motivating System. Primary outcome measured locomotor function and cardiopulmonary metabolic energy efficiency. Also, secondary outcome measured motor function and balance parameter. Results—: Compared with the control group, the experimental group had significantly greater improvement in spatiotemporal gait parameters and muscle efforts after the training intervention ( P <0.05). The net cardiopulmonary metabolic energy cost (mL·kg −1 ·min − 1 ) was also reduced by 14.71% in the experimental group after the intervention ( P <0.01). Significant group×time interactions were observed for all parameters ( P <0.05). Cardiopulmonary metabolic efficiency was strongly correlated with gait symmetry ratio in the experimental group ( P <0.01). Conclusions—: Gait training with Gait Enhancing and Motivating System was effective for improving locomotor function and cardiopulmonary metabolic energy efficiency during walking in patients with stroke. These findings suggest that robotic locomotor training can be adopted for rehabilitation of patients with stroke with gait disorders. Clinical Trial Registration—: URL: https://clinicaltrials.gov . Unique identifier: NCT02843828.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/strokeaha.119.025950

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 116

Metadata

Authors
Lee, H.-J., Lee, S.-H., Seo, K., Lee, M., Chang, W. H., Choi, B.-O., Ryu, G.-H., & Kim, Y.-H.
Venue
Stroke
Published
2019-12
Volume
50
Issue
12
Pages
3545-3552
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2983409913
Cited by
116
References
2
FWCI
7.65
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Training for Walking Efficiency With a Wearable Hip-Assist Robot in Patients With Stroke: A Pilot Randomized Controlled Trial. https://app.cochat.ai/papers/10.1161/strokeaha.119.025950
The paper
Lee, H.-J., Lee, S.-H., Seo, K., Lee, M., Chang, W. H., Choi, B.-O., Ryu, G.-H., & Kim, Y.-H. (2019). Training for Walking Efficiency With a Wearable Hip-Assist Robot in Patients With Stroke: A Pilot Randomized Controlled Trial. Stroke. https://doi.org/10.1161/strokeaha.119.025950

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.