Cited by 66Clinical Laboratory Practices and Quality ControlCentral Venous Catheters and HemodialysisBlood transfusion and management

The DOI matches its Crossref record; its reference list is not available.

Critical review and meta-analysis of spurious hemolysis in blood samples collected from intravenous catheters

Open access

Abstract

BACKGROUND: A number of preanalytical activities strongly influence sample quality, especially those related to sample collection. Since blood drawing through intravenous catheters is reported as a potential source of erythrocyte injury, we performed a critical review and meta-analysis about the risk of catheter-related hemolysis. MATERIALS AND METHODS: We performed a systematic search on PubMed, Web of Science and Scopus to estimate the risk of spurious hemolysis in blood samples collected from intravenous catheters. A meta-analysis with calculation of Odds ratio (OR) and Relative risk (RR) along with 95% Confidence interval (95% CI) was carried out using random effect mode. RESULTS: Fifteen articles including 17 studies were finally selected. The total number of patients was 14,796 in 13 studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes, and 1251 in 4 studies assessing catheter and evacuated tubes versus catheter and manual aspiration. A significant risk of hemolysis was found in studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes (random effect OR 3.4; 95% CI = 2.9-3.9 and random effect RR 1.07; 95% CI = 1.06-1.08), as well as in studies assessing catheter and evacuated tubes versus catheter and manual aspiration of blood (OR 3.7; 95% CI = 2.7-5.1 and RR 1.32; 95% CI = 1.24-1.40). CONCLUSIONS: Sample collection through intravenous catheters is associated with significant higher risk of spurious hemolysis as compared with standard blood drawn by straight needle, and this risk is further amplified when intravenous catheter are associated with primary evacuated blood tubes as compared with manual aspiration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.11613/bm.2013.022

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Catheter blood collection increases the risk of hemolysis.

    “We discourage blood sampling from an intravenous catheter, as it has been shown by many studies that catheter blood collection increases the risk of hemolysis [2], [3], [4].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 36 · Cited by 66

Research works printed but not linked: 32

  1. [1]Lippi G Chance JJ Church S Dazzi P Fontana R Giavarina D Preanalytical quality improvement: from dream to reality Clin Chem Lab Med 2011 49 1113 26 http://dx.doi.org/10.1515/cclm.2011.600 21517699 · DOI
  2. [2]Simundic AM Lippi G Preanalytical phase--a continuous challenge for laboratory professionals Biochem Med 2012 22 145 9 http://dx.doi.org/10.11613/BM.2012.017 PMC4062337 22838180 · DOI
  3. [3]Lippi G Salvagno GL Montagnana M Lima-Oliveira G Guidi GC Favaloro EJ Quality standards for sample collection in coagulation testing Semin Thromb Hemost 2012 38 565 75 http://dx.doi.org/10.1055/s-0032-1315961 22669757 · DOI
  4. [4]Simundic AM Topic E Nikolac N Lippi G Hemolysis detection and management of hemolysed specimens Biochem Med 2010 20 154 9 http://dx.doi.org/10.11613/BM.2010.018 · DOI
  5. [5]Carraro P Servidio G Plebani M Hemolyzed specimens: a reason for rejection or a clinical challenge? Clin Chem 2000 46 306 7 10657399
  6. [6]Lippi G Plebani M Di Somma S Cervellin G Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories Crit Rev Clin Lab Sci 2011 48 143 53 http://dx.doi.org/10.3109/10408363.2011.600228 21875312 · DOI
  7. [7]Lippi G Blanckaert N Bonini P Green S Kitchen S Palicka V Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories Clin Chem Lab Med 2008 46 764 72 http://dx.doi.org/10.1515/CCLM.2008.170 18601596 · DOI
  8. [8]Lippi G Avanzini P Pavesi F Bardi M Ippolito L Aloe R Favaloro EJ Studies on in vitro hemolysis and utility of corrective formulas for reporting results on hemolyzed specimens Biochem Med 2011 21 297 305 http://dx.doi.org/10.11613/BM.2011.040 22420244 · DOI
  9. [9]Lippi G Avanzini P Dipalo M Aloe R Cervellin G Influence of hemolysis on troponin testing: studies on Beckman Coulter UniCel Dxl 800 Accu-TnI and overview of the literature Clin Chem Lab Med 2011 49 2097 100 http://dx.doi.org/10.1515/CCLM.2011.703 21892912 · DOI
  10. [10]Heyer NJ Derzon JH Winges L Shaw C Mass D Snyder SR Effectiveness of practices to reduce blood sample hemolysis in EDs: a laboratory medicine best practices systematic review and meta-analysis Clin Biochem 2012 45 1012 32 http://dx.doi.org/10.1016/j.clinbiochem.2012.08.002 22968086 PMC4518461 · DOI
  11. [11]Halm MA Gleaves M Obtaining blood samples from peripheral intravenous catheters: best practice? Am J Crit Care 2009 18 474 8 http://dx.doi.org/10.4037/ajcc2009686 19723868 · DOI
  12. [12]Lippi G Favalor EJ Simundic AM Biomedical research platforms and their influence on article submissions and journal rankings: an update Biochem Med 2012 22 7 14 http://dx.doi.org/10.11613/BM.2012.002 PMC4062318 22384515 · DOI
  13. [13]Whiting P Rutjes AW Reitsma JB Bossuyt PM Kleijnen J The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews BMC Med Res Methodol 2003 3 25 http://dx.doi.org/10.1186/1471-2288-3-25 14606960 PMC305345 · DOI · Paper page
  14. [14]Agós MD Lizarraga R Gambra D Marañón A Orozco C Díaz E Factors related to haemolysis in the extraction of blood samples An Sist Sanit Navar 2008 31 153 8 18953363
  15. [15]Burns ER Hemolysis in serum samples drawn by emergency department personnel versus laboratory phlebotomists Lab Medicine 2002 33 378 80 http://dx.doi.org/10.1309/PGM4-4F8L-2P1M-LKPB · DOI
  16. [16]Dietrich H One Poke or Two: Can Intravenous Catheters Provide an Acceptable Blood Sample? A Data Set Presentation, Review of Previous Data Sets, and Discussion J Emerg Nurs 2013 [Epub ahead of print] http://dx.doi.org/10.1016/j.jen.2012.11.002. 23333158 · DOI
  17. [17]Fang L Fang SH Chung YH Chien ST Collecting factors related to the haemolysis of blood specimens J Clin Nurs 2008 17 2343 51 http://dx.doi.org/10.1111/j.1365-2702.2006.02057.x 18047574 · DOI
  18. [19]Grant MS The effect of blood drawing techniques and equipment on the hemolysis of ED laboratory blood samples J Emerg Nurs 2003 29 116 21 http://dx.doi.org/10.1067/men.2003.66 12660692 · DOI
  19. [20]Grant MS The effect of blood drawing techniques and equipment on the hemolysis of ED laboratory blood samples [Abstract] J Emerg Nurs 2003 29 406 http://dx.doi.org/10.1016/S0099-1767(03)00356-8. 12660692 · DOI
  20. [21]Kennedy C Angermuller S King R Noviello S Walker J Warden J Vang S A comparison of hemolysis rates using intravenous catheters versus venipuncture tubes for obtaining blood samples J Emerg Nurs 1996 22 566 9 http://dx.doi.org/10.1016/S0099-1767(96)80213-3. 9060320 · DOI
  21. [22]Lowe G Stike R Pollack M Bosley J O’Brien P Hake A Nursing blood specimen collection techniques and hemolysis rates in an emergency department: analysis of veni-puncture versus intravenous catheter collection techniques J Emerg Nurs 2008 34 26 32 http://dx.doi.org/10.1016/j.jen.2007.02.006 18237663 · DOI
  22. [23]Munnix IC Schellart M Gorissen C Kleinveld HA Factors reducing hemolysis rates in blood samples from the emergency department Clin Chem Lab Med 2011 49 157 8 http://dx.doi.org/10.1515/cclm.2011.012 20961194 · DOI
  23. [24]Ong ME Chan YH Lim CS Observational study to determine factors associated with blood sample haemolysis in the emergency department Ann Acad Med Singapore 2008 37 745 8 18989489
  24. [25]Straszewski SM Sanchez L McGillicuddy D Boyd K Dufresne J Joyce N Use of separate venipunctures for IV access and laboratory studies decreases hemolysis rates Intern Emerg Med 2011 6 357 9 http://dx.doi.org/10.1007/s11739-011-0568-9 21468698 · DOI
  25. [26]Seemann S Reinhardt A Blood sample collection from a peripheral catheter system compared with phlebotomy J Intraven Nurs 2000 23 290 7 11847740
  26. [27]Lippi G Avanzini P Cervellin G Prevention of hemolysis in blood samples collected from intravenous catheters Clin Biochem 2013 [Epub ahead of print] http://dx.doi.org/10.1016/j.clinbiochem.2013.01.021. 23391635 · DOI
  27. [28]Dugan L Leech L Speroni KG Corriher J Factors affecting hemolysis rates in blood samples drawn from newly placed IV sites in the emergency department J Emerg Nurs 2005 31 338 45 http://dx.doi.org/10.1016/j.jen.2005.05.004 16126097 · DOI
  28. [29]Lippi G Avanzini P Musa R Sandei F Aloe R Cervellin G Evaluation of sample hemolysis in blood collected by S-Monovette® using vacuum or aspiration mode Biochem Med 2013 23 64 9 http://dx.doi.org/10.11613/BM.2013.008 PMC3900093 23457766 · DOI
  29. [30]Plebani M Lippi G Hemolysis index: quality indicator or criterion for sample rejection? Clin Chem Lab Med 2009 47 899 902 http://dx.doi.org/10.1515/CCLM.2009.229 19642858 · DOI
  30. [31]Simundic AM Nikolac N Ivankovic V Ferenec-Ruzic D Magdic B Kvaternik M Topic E Comparison of visual vs. automated detection of lipemic, icteric and hemolyzed specimens: can we rely on a human eye? Clin Chem Lab Med 2009 47 1361 5 http://dx.doi.org/10.1515/CCLM.2009.306 19778291 · DOI
  31. [32]Lippi G Luca Salvagno G Blanckaert N Giavarina D Green S Kitchen S Multicenter evaluation of the hemolysis index in automated clinical chemistry systems Clin Chem Lab Med 2009 47 934 9 http://dx.doi.org/10.1515/CCLM.2009.218 19548845 · DOI
  32. [33]Lippi G Plebani M Continuous-Flow Automation and Hemolysis Index: A Crucial Combination J Lab Autom 2012 [Epub ahead of print] 22713757

Metadata

Authors
Lippi, G., Cervellin, G., & Mattiuzzi, C.
Affiliations
Ospedale di Parma (IT)
Corresponding author
Lippi, Giuseppe
Venue
Biochemia Medica
Published
2013
Volume
23
Issue
2
Pages
193-200
ISSN
  • 1330-0962 (ISSN-L)
  • 1846-7482
OpenAlex
W2141045421
Cited by
66
References
36
Citations by year
2026: 2 · 2025: 1 · 2024: 5 · 2023: 7 · 2022: 4 · 2021: 5 · 2020: 5 · 2019: 12 · 2018: 3 · 2017: 5 · 2016: 4 · 2015: 8 · 2014: 3 · 2013: 2
FWCI
0.62
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Biochemia Medica (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • Hrčak Portal of scientific journals of Croatia (University Computing Centre) (submittedVersion, other-oa)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
  • Health Sciences › Medicine › Hematology › Blood transfusion and management
Keywords
intravenous catheters, blood sampling, pre-analytical variables, manual vacuum aspiration, sample quality
MeSH terms
Catheters, Indwelling, Hemolysis, Humans, Veins

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review