Multi-modality Imaging Identifies Key Times for Annexin V Imaging as an Early Predictor of Therapeutic Outcome
Open accessThe DOI matches its Crossref record.
Abstract
Radiolabeled annexin V may provide an early indication of the success or failure of anticancer therapy on a patient-by-patient basis as an in vivo marker of tumor cell killing. An important question that remains is when, after initiation of treatment, should annexin V imaging be performed. To address this issue, we obtained simultaneous in vivo measurements of tumor burden and uptake of radiolabeled annexin V in the syngeneic orthotopic murine BCL 1 lymphoma model using in vivo bioluminescence imaging (BLI) and small animal single-photon emission computed tomography (SPECT). BCL 1 cells labeled for fluorescence and bioluminescence assays (BCL 1− gfp/luc) were injected into mice at a dose that leads to progressive disease within two to three weeks. Tumor response was followed by BLI and SPECT before and after treatment with a single dose of 10 mg/kg doxorubicin. Biodistribution analyses revealed a biphasic increase of annexin V uptake within the tumor-bearing tissues of mice. An early peak occurring before actual tumor cells loss was observed between 1 and 5 hr after treatment, and a second longer sustained rise from 9 to 24 hr after therapy, which heralds the onset of tumor cell loss as confirmed by BLI. Multimodality imaging revealed the temporal patterns of tumor cell loss and annexin V uptake revealing a better understanding of the timing of radiolabeled annexin V uptake for its development as a marker of therapeutic efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Liu, H., Patel, M. R., Prescher, J. A., Patsialou, A., Qian, D., Lin, J., Wen, S., Chang, Y.-F., Bachmann, M. H., Shimono, Y., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006732107 · Cited by 465
Self-citationArbab, A. S., Yocum, G. T., Rad, A. M., Khakoo, A. Y., Fellowes, V., Read, E. J., & Frank, J. A. (2005) · NMR in Biomedicine · doi:10.1002/nbm.991 · Cited by 297
PET/CT imaging in cancer: current applications and future directions
Farwell, M. D., Pryma, D. A., & Mankoff, D. A. (2014) · Cancer · doi:10.1002/cncr.28860 · Cited by 230
Tumor-Specific Positron Emission Tomography Imaging in Patients: [18F] Fluorodeoxyglucose and Beyond
Mankoff, D. A., Eary, J. F., Link, J. M., Muzi, M., Rajendran, J. G., Spence, A. M., & Krohn, K. A. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-07-0074 · Cited by 175
Advances in imaging mouse tumour models in vivo
Lyons, S. K. (2005) · The Journal of Pathology · doi:10.1002/path.1697 · Cited by 174
Metadata
- Authors
- Mandl, S. J., Mari, C., Edinger, M., Negrin, R. S., Tait, J. F., Contag, C. H., & Blankenberg, F. G.
- Venue
- Molecular Imaging
- Publisher
- SAGE Publications
- Published
- 2004-01-01
- Volume
- 3
- Issue
- 1
- Pages
- 1-8
- ISSN
- 1535-3508 (ISSN-L)
- 1536-0121
- OpenAlex
- W1983985735
- Cited by
- 65
- References
- 0
- FWCI
- 7.22
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.