Role of Thermo-responsiveness and Poly(ethylene glycol) Diacrylate Cross-link Density on Protein Release from Poly(N-isopropylacrylamide) Hydrogels
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Thermo-responsive hydrogels have shown promise as injectable materials for local drug delivery. However, the phase-induced changes in polymer properties of N-isopropylacrylamide (NIPAAm) can pose additional challenges for achieving controlled protein release. In this work, thermo-responsive hydrogels derived from NIPAAm and cross-linked with poly(ethylene glycol) diacrylate (PEG-DA) were synthesized via free radical polymerization. The volume phase transition temperature (VPTT) of the hydrogels ranged from 32.9°C to 35.9°C. Below the VPTT, swelling ratios of the hydrogels decreased with cross-linker concentration, and showed a sharp drop (at least 4-fold) upon phase change. Protein encapsulation efficiency was high (84-90%) and decreased with cross-linker concentration. Release of bovine serum albumin, a model protein, at body temperature was significantly higher than at room temperature (67% at 37°C compared to 44% at 23°C after 48 h). The release kinetics of proteins from the hydrogels were initially expected to be a function of cross-link density. However, at the hydrogel compositions explored in this work, protein release did not change significantly with cross-linker mol fraction. The thermo-responsive hydrogels offer a promising platform for the localized delivery of proteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermoresponsive hydrogels in biomedical applications
Klouda, L., & Mikos, A. G. (2008) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2007.02.025 · Cited by 1,349
Drug targeting using thermally responsive polymers and local hyperthermia
Meyer, D. E., Shin, B. C., Kong, G. A., Dewhirst, M. W., & Chilkoti, A. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00319-4 · Cited by 416
Prabaharan, M., & Mano, J. F. (2006) · Macromolecular Bioscience · doi:10.1002/mabi.200600164 · Cited by 347
Cited by
Alexander, A., Ajazuddin, Khan, J., Saraf, S., & Saraf, S. (2014) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2014.07.005 · Cited by 249
Principles of pharmacology in the eye
Awwad, S., Mohamed Ahmed, A. H. A., Sharma, G., Heng, J. S., Khaw, P. T., Brocchini, S., & Lockwood, A. (2017) · British Journal of Pharmacology · doi:10.1111/bph.14024 · Cited by 224
“One thermosensitive material that shows gel–sol transition is poly(N-isopropylacrylamide) (pNIPAAM) (Yıldız et al., 2002; Silva and Oliveira, 2007; Li et al., 2008; Drapala et al., 2011; Klouda, 2015).”
Kang-Mieler, J. J., Dosmar, E., Liu, W., & Mieler, W. F. (2017) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2016.1227785 · Cited by 73
Self-citation
Metadata
- Authors
- Drapala, P. W., Brey, E. M., Mieler, W. F., Venerus, D. C., Kang Derwent, J. J., & Pérez-Luna, V. H.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 2011-01
- Volume
- 22
- Issue
- 1-3
- Pages
- 59-75
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W2070707443
- Cited by
- 40
- References
- 3
- FWCI
- 0.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Role of Thermo-responsiveness and Poly(ethylene glycol) Diacrylate Cross-link Density on Protein Release from Poly(N-isopropylacrylamide) Hydrogels. https://app.cochat.ai/papers/10.1163/092050609x12578498952315
- The paper
- Drapala, P. W., Brey, E. M., Mieler, W. F., Venerus, D. C., Kang Derwent, J. J., & Pérez-Luna, V. H. (2011). Role of Thermo-responsiveness and Poly(ethylene glycol) Diacrylate Cross-link Density on Protein Release from Poly(N-isopropylacrylamide) Hydrogels. Journal of Biomaterials Science, Polymer Edition. https://doi.org/10.1163/092050609x12578498952315
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.