Amorphous Calcium Phosphate Composites and Their Effect on Composite–Adhesive–Dentin Bonding
Open accessThe DOI matches its Crossref record.
Abstract
This study evaluates the bond strength and related properties of photo-polymerizable, remineralizing amorphous calcium phosphate (ACP) polymeric composite-adhesive systems to dentin after various periods of aqueous aging at 37 °C. An experimental ACP base and lining composite was made from a photo-activated resin comprising 2,2-bis[p-(2'-hydroxy-3'-methacryloxypropoxy)phenyl]propane (Bis-GMA), triethylene glycol dimethacrylate (TEGDMA), 2-hydroxyethyl methacrylate (HEMA) and zirconyl dimethacrylate (ZrDMA); designated BTHZ. An experimental orthodontic composite was formulated from a photo-activated resin comprising ethoxylated bisphenol A dimethacrylate (EBPADMA), TEGDMA, HEMA and methacryloxyethyl phthalate (MEP); designated ETHM. In both composite series three fillers were compared: 1) freshly precipitated zirconium-modified ACP freshly precipitated (as-prepared Zr-ACP), 2) milled Zr-ACP and 3) an ion-leachable fluoride glass. In addition to the shear bond strength (SBS), work to fracture and failure modes of the orthodontic composites were determined. The SBS of the base and lining ACP composites appeared unaffected by filler type or immersion time. In the orthodontic ACP composite series, milled ACP composites showed initial mechanical advantages over as-prepared ACP composites, and produced higher incidence of a failure mode consistent with stronger adhesion. After six months of aqueous exposure, 80 % of specimens failed at the dentin-primer interface, with a 42 % overall reduction in bond strength. BTHZ and ETHM based ACP composites are potentially effective anti-demineralizing-remineralizing agents with possible clinical utility as protective base-liners and orthodontic cements, respectively. The analysis of the bond strength and failure modalities suggests that milled ACP composites may offer greater potential in clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Eliaz, N., & Metoki, N. (2017) · Materials · doi:10.3390/ma10040334 · Cited by 1,088
Amorphous calcium phosphates: Synthesis, properties and uses in biomaterials
Combes, C., & Rey, C. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.017 · Cited by 752
Amorphous calcium (ortho)phosphates
Dorozhkin, S. V. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.06.031 · Cited by 485
Novel dental adhesives containing nanoparticles of silver and amorphous calcium phosphate
Melo, M. A. S., Cheng, L., Zhang, K., Weir, M. D., Rodrigues, L. K. A., & Xu, H. H. K. (2013) · Dental Materials · doi:10.1016/j.dental.2012.10.005 · Cited by 259
Anti-biofilm dentin primer with quaternary ammonium and silver nanoparticles
Cheng, L., Zhang, K., Melo, M. A. S., Weir, M. D., Zhou, X., & Xu, H. H. K. (2012) · Journal of Dental Research · doi:10.1177/0022034512444128 · Cited by 183
“A stainless-steel iris having a central opening (diameter = 4 mm, thickness = 1.5 mm) was held against the adhesive-treated dentin (Antonucci et al., 2009).”
MethodInfluential
Metadata
- Authors
- Antonucci, J. M., O'Donnell, J. N. R., Schumacher, G. E., & Skrtic, D.
- Venue
- Journal of Adhesion Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2009-01
- Volume
- 23
- Issue
- 7-8
- Pages
- 1133-1147
- ISSN
- 0169-4243 (ISSN-L)
- 1568-5616
- OpenAlex
- W2027596913
- Cited by
- 46
- References
- 0
- FWCI
- 6.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Amorphous Calcium Phosphate Composites and Their Effect on Composite–Adhesive–Dentin Bonding. https://app.cochat.ai/papers/10.1163/156856109x432767
- The paper
- Antonucci, J. M., O'Donnell, J. N. R., Schumacher, G. E., & Skrtic, D. (2009). Amorphous Calcium Phosphate Composites and Their Effect on Composite–Adhesive–Dentin Bonding. Journal of Adhesion Science and Technology. https://doi.org/10.1163/156856109x432767
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.