Effects on protein adsorption, bacterial adhesion and contact angle of grafting PEG chains to polystyrene
The DOI matches its Crossref record.
Abstract
Poly(ethylene glycol) (PEG) has been grafted to polystyrene using branched poly(ethylene imine) (PEI) as an anchoring polymer. A dense grafting of PEG chains is obtained if a PEG-PEI adduct is first prepared by treatment of PEI with PEG epoxide and the adduct subsequently adsorbed on an oxidized polystyrene surface. Prepared in this way, the PEG-PEI adduct is irreversibly attached to the surface with the PEG chains oriented towards the aqueous phase, as shown by ellipsometry. This dense PEG coating is highly effective in preventing adsorption of fibrinogen and IgG, as well as adhesion of the oral bacterium Streptococcus mutans. Somewhat surprisingly, the degree of PEG branching, as well as the PEG molecular weight, did not markedly influence protein repelling properties. The water contact angle on polystyrene decreased in the order: untreated polystyrene > oxidized > PEI treated > PEG-PEI treated. Block copolymers of poly(ethylene glycol)/poly(propylene glycol) type attached to polystyrene showed temperature dependent protein rejecting properties. At temperatures well below the cloud point of the polymer in water, the surface is protein repellent whereas around and above the cloud point, protein adsorption occurs to a considerable extent. The block copolymer layer expands and contracts with temperature variations, as can be monitored by ellipsometry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PEGylated nanoparticles for biological and pharmaceutical applications
Otsuka, H., Nagasaki, Y., & Kataoka, K. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00226-0 · Cited by 1,588
Polymer surface modification for the attachment of bioactive compounds
Goddard, J. M., & Hotchkiss, J. H. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.04.002 · Cited by 1,379
Inhibition of bacterial adhesion and biofilm formation on zwitterionic surfaces
Cheng, G., Zhang, Z., Chen, S., Bryers, J. D., & Jiang, S. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.05.041 · Cited by 729
Significance of bacterial surface-active compounds in interaction of bacteria with interfaces
Neu, T. R. (1996) · Microbiological Reviews · doi:10.1128/mmbr.60.1.151-166.1996 · Cited by 667
Lichter, J. A., Van Vliet, K. J., & Rubner, M. F. (2009) · Macromolecules · doi:10.1021/ma901356s · Cited by 478
Metadata
- Authors
- Holmberg, K., Bergström, K., Brink, C., Österberg, E., Tiberg, F., & Harris, J. M.
- Venue
- Journal of Adhesion Science and Technology
- Publisher
- Informa UK Limited
- Published
- 1993-01
- Volume
- 7
- Issue
- 6
- Pages
- 503-517
- ISSN
- 0169-4243 (ISSN-L)
- 1568-5616
- OpenAlex
- W1968027268
- Cited by
- 74
- References
- 0
- FWCI
- 1.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects on protein adsorption, bacterial adhesion and contact angle of grafting PEG chains to polystyrene. https://app.cochat.ai/papers/10.1163/156856193x00826
- The paper
- Holmberg, K., Bergström, K., Brink, C., Österberg, E., Tiberg, F., & Harris, J. M. (1993). Effects on protein adsorption, bacterial adhesion and contact angle of grafting PEG chains to polystyrene. Journal of Adhesion Science and Technology. https://doi.org/10.1163/156856193x00826
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.