Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 160

The DOI matches its Crossref record.

Limits of detection for time of flight secondary ion mass spectrometry (ToF-SIMS) and X-ray photoelectron spectroscopy (XPS): detection of low amounts of adsorbed protein

Wagner, Matthew S., McArthur, Sally L., Shen, Mingchao, Horbett, Thomas A., Castner, David G.·2002·Journal of Biomaterials Science, Polymer Edition

Abstract

Characterization of biomaterial surfaces requires analytical techniques that are capable of detecting a wide concentration range of adsorbed protein. This range includes detection of low amounts of adsorbed protein (<10 ng/cm2) that may be present on non-fouling biomaterials. X-ray Photoelectron Spectroscopy (XPS) and Time of Flight Secondary Ion Mass Spectrometry (ToF-SIMS) are surface sensitive techniques capable of detecting adsorbed proteins. We have investigated the lower limits of detection of both XPS and ToF-SIMS on four model substrates each presenting unique challenges for analysis by XPS and ToF-SIMS: mica, poly(tetrafluoroethylene), allyl amine plasma polymer and heptyl amine plasma polymer. The detection limit for XPS ranged from 10 ng/cm2 of fibrinogen (on mica) to 200 ng/cm2 (on allyl amine plasma polymers). The detection limit for ToF-SIMS ranged from 0.1 ng/cm2 of fibrinogen to 100 ng/cm2, depending on the substrate and data analysis. Optimal conditions provided detection limits between 0.1 ng/cm2 and 15 ng/cm2 on all of the substrates used in this study. While both techniques were shown to be effective in detecting protein, the sensitivity of both XPS and ToF-SIMS was shown to be dependent on substrate surface chemistry and the organization of the adsorbed protein film. This study specifically highlights the applicability of ToF-SIMS in the characterization of low level protein adsorption.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1163/156856202320253938

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 160

Metadata

Authors
Wagner, M. S., McArthur, S. L., Shen, M., Horbett, T. A., & Castner, D. G.
Venue
Journal of Biomaterials Science, Polymer Edition
Published
2002-01
Volume
13
Issue
4
Pages
407-428
ISSN
  • 0920-5063 (ISSN-L)
  • 1568-5624
OpenAlex
W2115640378
Cited by
160
References
0
FWCI
4.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Limits of detection for time of flight secondary ion mass spectrometry (ToF-SIMS) and X-ray photoelectron spectroscopy (XPS): detection of low amounts of adsorbed protein. https://app.cochat.ai/papers/10.1163/156856202320253938
The paper
Wagner, M. S., McArthur, S. L., Shen, M., Horbett, T. A., & Castner, D. G. (2002). Limits of detection for time of flight secondary ion mass spectrometry (ToF-SIMS) and X-ray photoelectron spectroscopy (XPS): detection of low amounts of adsorbed protein. Journal of Biomaterials Science, Polymer Edition. https://doi.org/10.1163/156856202320253938

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.