CoChat

Protein release from poly(ε-caprolactone) microspheres prepared by melt encapsulation and solvent evaporation techniques: A comparative study

Jameela, S.R., Suma, N., Jayakrishnan, A. · 1997 · Journal of Biomaterials Science, Polymer Edition
Cited by 113

The DOI matches its Crossref record.

Abstract

Poly(epsilon-caprolactone) (PCL) microspheres containing c. 3% bovine serum albumin (BSA) were prepared by melt encapsulation and solvent evaporation techniques. PCL, because of its low Tm, enabled the melt encapsulation of BSA at 75 degrees C thereby avoiding potentially toxic organic solvents such as dichloromethane (DCM). Unlike the solvent evaporation method, melt encapsulation led to 100% incorporation efficiency which is a key factor in the microencapsulation of water-soluble drugs. Examination of the stability of the encapsulated protein by sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE) demonstrated that protein integrity was unaffected by both methods of encapsulation. In vitro release of the protein into phosphate buffer examined at 37 degrees C from microspheres prepared by both techniques showed that the release rate from melt-encapsulated microspheres was somewhat slower compared to the release from solvent-evaporated spheres. Both released around 20% of the incorporated protein in 2 weeks amounting to approximately 6.5 micrograms mg-1 of microspheres. Although the diffusivity of macromolecules in PCL is rather low, it is shown that PCL microspheres are capable of delivering sufficient quantity of proteins by diffusion for prolonged periods to function as a carrier for many vaccines. Unlike poly(lactic acid) (PLA) and poly(glycolic acid) (PGA) polymers which generate extreme acid environments during their degradation, the delayed degradation characteristics of PCL do not generate an acid environment during protein release and, therefore, may be advantageous for sustained delivery of proteins and polypeptides.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1163/156856297x00380

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 113

Metadata

Authors
Jameela, S. R., Suma, N., & Jayakrishnan, A.
Venue
Journal of Biomaterials Science, Polymer Edition
Published
1997-01
Volume
8
Issue
6
Pages
457-466
ISSN
  • 0920-5063 (ISSN-L)
  • 1568-5624
OpenAlex
W1978841037
Cited by
113
References
0
FWCI
2.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Protein release from poly(ε-caprolactone) microspheres prepared by melt encapsulation and solvent evaporation techniques: A comparative study. https://app.cochat.ai/papers/10.1163/156856297x00380
The paper
Jameela, S. R., Suma, N., & Jayakrishnan, A. (1997). Protein release from poly(ε-caprolactone) microspheres prepared by melt encapsulation and solvent evaporation techniques: A comparative study. Journal of Biomaterials Science, Polymer Edition. https://doi.org/10.1163/156856297x00380

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.