Bovine serum albumin adsorption onto immobilized organotrichlorosilane surface: Influence of the phase separation on protein adsorption patterns
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Octadecyltrichlorosilane (OTS) and [2-(perfluorooctyl)ethyl]trichlorosilane (FOETS) monolayers and their mixed monolayer were polymerized on a water subphase and subsequently immobilized onto a silicon wafer surface by covalent bonding. Atomic force microscopic (AFM) observation of the mixed (OTS/FOETS) monolayer revealed the formation of a phase-separated structure. Protein-adsorption behavior onto the monolayers was investigated in situ on the basis of an attenuated total reflection Fourier transform infrared (ATR-FT-IR) spectroscopic flow cell method and the morphology of the monolayer surface-adsorbed bovine serum albumin (BSA) was observed by AFM. Protein adsorption behavior observed by ATR-FT-IR flow cell method revealed that the amount of BSA adsorption onto the OTS and FOETS monolayers increased remarkably at an initial experimental stage and attained a steady state within a few minutes at pH 7.5. The amount of steady state adsorption was c. 0.18-0.2 microgcm(-2). AFM observation of the monolayer after exposure to BSA solution suggested that BSA adsorbed in the end-on adsorption state on OTS monolayer and side-on one in the FOETS monolayer, respectively. However, in the case of the mixed (OTS/FOETS) monolayer, ATR-FT-IR flow cell experiment revealed that the amount of steady state adsorption of BSA was suppressed. Also, AFM observation revealed that at pH 7.5, BSA preferentially adsorbed onto the FOETS phase of the mixed (OTS/FOETS) monolayer, which had a higher interfacial free energy against water. On the other hand, BSA adsorbed homogeneously onto the OTS and FOETS phases at the isoelectric point of BSA (pH 4.7). These results indicate that the preferential adsorption of BSA onto the FOETS phase in the mixed (OTS/FOETS) monolayer system is due to: (1) the minimization of the interfacial free energy between a monolayer surface and an aqueous solution; and (2) the electrostatic repulsion between BSA molecules bearing negative charges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of the surface free energy of polymers
Owens, D. K., & Wendt, R. C. (1969) · Journal of Applied Polymer Science · doi:10.1002/app.1969.070130815 · Cited by 9,476
Computed circular dichroism spectra for the evaluation of protein conformation
Greenfield, N. J., & Fasman, G. D. (1969) · Biochemistry · doi:10.1021/bi00838a031 · Cited by 3,694
Peters, T. (1985) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(08)60065-0 · Cited by 2,181
Acid—base interfacial interactions in aqueous media
van Oss, C. J. (1993) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/0927-7757(93)80308-2 · Cited by 938
Proteins at Interfaces II: Fundamentals and Applications
(1995) · ACS Symposium Series · doi:10.1021/bk-1995-0602 · Cited by 555
Proteins at Interfaces: Physicochemical and Biochemical Studies
(1987) · ACS Symposium Series · doi:10.1021/bk-1987-0343 · Cited by 267
Van Dulm, P., & Norde, W. (1983) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(83)90329-6 · Cited by 161
Takahara, A., Tashita, J., Kajiyama, T., Takayanagi, M., & MacKnight, W. J. (1985) · Polymer · doi:10.1016/0032-3861(85)90218-6 · Cited by 125
Self-citationProtein tracking and detection of protein motion using atomic force microscopy
Thomson, N. H., Fritz, M., Radmacher, M., Cleveland, J. P., Schmidt, C. F., & Hansma, P. K. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79812-0 · Cited by 125
Sequential protein adsorption and thrombus deposition on polymeric biomaterials
Pitt, W. G., Park, K., & Cooper, S. L. (1986) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(86)90039-1 · Cited by 115
Cited by
Luan, J., Seth, A., Gupta, R., Wang, Z., Rathi, P., Cao, S., Gholami Derami, H., Tang, R., Xu, B., Achilefu, S., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0547-4 · Cited by 201
Controllable transition from finger-like pores to inter-connected pores of PLLA membranes
Gao, A., Liu, F., Shi, H., & Xue, L. (2015) · Journal of Membrane Science · doi:10.1016/j.memsci.2015.01.004 · Cited by 88
Al‐Abboodi, A., Tjeung, R., Doran, P. M., Yeo, L. Y., Friend, J., & Yik Chan, P. P. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201400072 · Cited by 27
Metadata
- Authors
- Ge, S., Kojio, K., Takahara, A., & Kajiyama, T.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 1998-01
- Volume
- 9
- Issue
- 2
- Pages
- 131-150
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W2060045494
- Cited by
- 193
- References
- 13
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.