Interaction of fibroblasts on polycarbonate membrane surfaces with different micropore sizes and hydrophilicity
The DOI matches its Crossref record.
Abstract
Surface topography appears to be an important but often neglected factor in implant performance. In this study, fibroblasts were cultured on a range of porous polycarbonate (PC) membranes with well defined surface topography (track-etched micropores, 0.2-8.0 microm in diameter) and wettability gradients. The wettability gradient on the PC membrane surfaces was produced by treating the surfaces with corona from a knife-type electrode whose power increased gradually along the sample length. The PC membrane surfaces were characterized by scanning electron microscopy (SEM) and the water contact angle measurement. Fibroblasts were cultured on the corona-treated PC membrane surfaces with different micropore sizes for 1 and 2 days. The cells attached on the membrane surfaces were examined by SEM and the cell density on the surfaces was estimated by counting the number of attached cells along the wettability gradient. It was observed that the cells were adhered and grew more on the hydrophilic positions of the membrane surfaces than the more hydrophobic ones, regardless of micropore size. It was also observed that cell adhesion and growth decreased gradually with increasing micropore size of the membrane surfaces. It seems that the cell adhesion and growth were progressively inhibited as the membrane surfaces had micropores with increasing size, probably due to surface discontinuities produced by tract-etched pores. On the membrane surfaces with smaller micropore sizes, the cells seemed to override these surface discontinuities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Design, fabrication and characterization of PCL electrospun scaffolds—a review
Cipitria, A., Skelton, A., Dargaville, T. R., Dalton, P. D., & Hutmacher, D. W. (2011) · Journal of Materials Chemistry · doi:10.1039/c0jm04502k · Cited by 627
Choi, J. S., Lee, S. J., Christ, G. J., Atala, A., & Yoo, J. J. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.031 · Cited by 611
Self-citationSurface modification and property analysis of biomedical polymers used for tissue engineering
Ma, Z., Mao, Z., & Gao, C. (2007) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2007.06.019 · Cited by 590
Surface micropatterning to regulate cell functions
Ito, Y. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00162-3 · Cited by 500
Khang, G., Bang Lee, H., & Ho Lee, J. (2002) · Biomaterials · doi:10.1201/9781420040036.ch3 · Cited by 407
Self-citation
Metadata
- Authors
- Lee, J. H., Lee, S. J., Khang, G., & Lee, H. B.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 1999-01
- Volume
- 10
- Issue
- 3
- Pages
- 283-294
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W2065092363
- Cited by
- 101
- References
- 0
- FWCI
- 4.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interaction of fibroblasts on polycarbonate membrane surfaces with different micropore sizes and hydrophilicity. https://app.cochat.ai/papers/10.1163/156856299x00351
- The paper
- Lee, J. H., Lee, S. J., Khang, G., & Lee, H. B. (1999). Interaction of fibroblasts on polycarbonate membrane surfaces with different micropore sizes and hydrophilicity. Journal of Biomaterials Science, Polymer Edition. https://doi.org/10.1163/156856299x00351
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.